Literature DB >> 25333154

Improved screw placement for slipped capital femoral epiphysis (SCFE) using robotically-assisted drill guidance.

Bamshad Azizi Koutenaei, Ozgur Guler, Emmanuel Wilson, Ramesh U Thoranaghatte, Matthew Oetgen, Nassir Navab, Kevin Cleary.   

Abstract

Slipped Capital Femoral Epiphysis (SCFE) is a common hip displacement condition in adolescents. In the standard treatment, the surgeon uses intra-operative fluoroscopic imaging to plan the screw placement and the drill trajectory. The accuracy, duration, and efficacy of this procedure are highly dependent on surgeon skill. Longer procedure times result in higher radiation dose, to both patient and surgeon. A robotic system to guide the drill trajectory might help to reduce screw placement errors and procedure time by reducing the number of passes and confirmatory fluoroscopic images needed to verify accurate positioning of the drill guide along a planned trajectory. Therefore, with the long-term goals of improving screw placement accuracy, reducing procedure time and intra-operative radiation dose, our group is developing an image-guided robotic surgical system to assist a surgeon with pre-operative path planning and intra-operative drill guide placement.

Entities:  

Mesh:

Year:  2014        PMID: 25333154      PMCID: PMC4205479          DOI: 10.1007/978-3-319-10404-1_61

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  7 in total

1.  Evaluation of a portable image overlay projector for the visualisation of surgical navigation data: phantom studies.

Authors:  K Gavaghan; T Oliveira-Santos; M Peterhans; M Reyes; H Kim; S Anderegg; S Weber
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-10-21       Impact factor: 2.924

2.  Image-guided laser projection for port placement in minimally invasive surgery.

Authors:  Jonathan Marmurek; Chris Wedlake; Utsav Pardasani; Roy Eagleson; Terry Peters
Journal:  Stud Health Technol Inform       Date:  2006

3.  Augmented reality and image overlay navigation with OsiriX in laparoscopic and robotic surgery: not only a matter of fashion.

Authors:  Francesco Volonté; François Pugin; Pascal Bucher; Maki Sugimoto; Osman Ratib; Philippe Morel
Journal:  J Hepatobiliary Pancreat Sci       Date:  2011-07       Impact factor: 7.027

4.  Least-squares fitting of two 3-d point sets.

Authors:  K S Arun; T S Huang; S D Blostein
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1987-05       Impact factor: 6.226

5.  Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study.

Authors:  Norbert Suhm; Peter Messmer; Ivan Zuna; Ludwig A Jacob; Pietro Regazzoni
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

6.  Simultaneous use of cannulated reamer and schanz screw for closed intramedullary femoral nailing.

Authors:  Rajesh Rohilla; Roop Singh; Narender K Magu; Ashish Devgan; Ramchander Siwach; Sukhbir Singh Sangwan
Journal:  ISRN Surg       Date:  2011-04-11

7.  The image-guided surgery toolkit IGSTK: an open source C++ software toolkit.

Authors:  Andinet Enquobahrie; Patrick Cheng; Kevin Gary; Luis Ibanez; David Gobbi; Frank Lindseth; Ziv Yaniv; Stephen Aylward; Julien Jomier; Kevin Cleary
Journal:  J Digit Imaging       Date:  2007-08-17       Impact factor: 4.056

  7 in total
  2 in total

1.  Radiation-free methods for navigated screw placement in slipped capital femoral epiphysis surgery.

Authors:  Bamshad Azizi Koutenaei; Javad Fotouhi; Farshid Alambeigi; Emmanuel Wilson; Ozgur Guler; Mathew Oetgen; Kevin Cleary; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-18       Impact factor: 2.924

2.  Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery.

Authors:  Jessica Magaraggia; Wei Wei; Markus Weiten; Gerhard Kleinszig; Sven Vetter; Jochen Franke; Adrian John; Adrian Egli; Karl Barth; Elli Angelopoulou; Joachim Hornegger
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-05       Impact factor: 2.924

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.