Literature DB >> 25332300

Derivation and application of dose reduction factors for protective eyewear worn in interventional radiology and cardiology.

Jill S Magee1, Colin J Martin, Viktor Sandblom, Matthew J Carter, Anja Almén, Åke Cederblad, Pernilla Jonasson, Charlotta Lundh.   

Abstract

Doses to the eyes of interventional radiologists and cardiologists could exceed the annual limit of 20 mSv proposed by the International Commission on Radiological Protection. Lead glasses of various designs are available to provide protection, but standard eye dosemeters will not take account of the protection they provide. The aim of this study has been to derive dose reduction factors (DRFs) equal to the ratio of the dose with no eyewear, divided by that when lead glasses are worn. Thirty sets of protective eyewear have been tested in x-ray fields using anthropomorphic phantoms to simulate the patient and clinician in two centres. The experiments performed have determined DRFs from simulations of interventional procedures by measuring doses to the eyes of the phantom representing the clinician, using TLDs in Glasgow, Scotland and with an electronic dosemeter in Gothenburg, Sweden. During interventional procedures scattered x-rays arising from the patient will be incident on the head of the clinician from below and to the side. DRFs for x-rays incident on the front of lead glasses vary from 5.2 to 7.6, while values for orientations similar to those used in the majority of clinical practice are between 1.4 and 5.2. Specialised designs with lead glass side shields or of a wraparound style with angled lenses performed better than lead glasses based on the design of standard spectacles. Results suggest that application of a DRF of 2 would provide a conservative factor that could be applied to personal dosemeter measurements to account for the dose reduction provided by any type of lead glasses provided certain criteria relating to design and consistency of use are applied.

Entities:  

Mesh:

Year:  2014        PMID: 25332300     DOI: 10.1088/0952-4746/34/4/811

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  4 in total

1.  Occupational dose constraints for the lens of the eye for interventional radiologists and interventional cardiologists in the UK.

Authors:  William DA Mairs
Journal:  Br J Radiol       Date:  2016-03-24       Impact factor: 3.039

2.  Angular dependence of shielding effect of radiation protective eyewear for radiation protection of crystalline lens.

Authors:  Yuma Hirata; Toshioh Fujibuchi; Katsuya Fujita; Takayuki Igarashi; Eiji Nishimaru; Shogo Horita; Reiko Sakurai; Koji Ono
Journal:  Radiol Phys Technol       Date:  2019-10-15

Review 3.  Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures.

Authors:  Masaaki Akahane; Naoki Yoshioka; Shigeru Kiryu
Journal:  Interv Radiol (Higashimatsuyama)       Date:  2022-07-01

Review 4.  Radiation safety for pain physicians: principles and recommendations.

Authors:  Sewon Park; Minjung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2022-04-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.