Literature DB >> 25331579

Correlation of structural and electrophysiological changes in the retina of young high myopes.

Victor Koh1, Clement Tan, Gerard Nah, Paul Zhao, Adeline Yang, Sheng Tong Lin, Tien Yin Wong, Seang Mei Saw, Audrey Chia.   

Abstract

PURPOSE: Despite a high prevalence of myopia among young East Asian adults, there is a lack of data on the myopic retina structure-function relationship in this group. We examined the association between optical coherence tomography (OCT) and electroretinogram (ERG) measurements in highly myopic young Asian adults to provide this information and also determined if OCT can be used as an alternative screening tool to assess retinal function in young myopic adults.
METHODS: This was a prospective study comprising young adults aged between 18 and 25 years with spherical equivalent refraction of worse than -6.00 D. A comprehensive ophthalmic examination comprising fundus examination and grading, ocular biometry, time-domain OCT (fovea, macular and retinal nerve fibre layer thickness) and ERG (full field and multifocal) were performed for all the eyes.
RESULTS: A total of 32 eyes (mean spherical equivalent ± standard deviation -10.17 ± 1.51 D, mean age 23.8 ± 1.3 years) were included. None of the eyes showed visible myopic retinopathy and the central retina thickness of all eyes was classified as within the normal range. Full-field ERG amplitude and multifocal ERG P1 amplitudes in the outer rings (R3-R5) were, however, inversely associated with axial length. The multifocal ERG P1 amplitudes were also positively correlated with mean retinal nerve fibre layer thickness in R2, 4, 5 rings and outer macular thickness in R 2-5 rings.
CONCLUSION: These findings suggest that full field ERG changes may precede fundus and OCT changes in highly myopic young adults. Although there was some correlation between multifocal ERG amplitudes with OCT outer macular and retinal nerve fibre layer thickness, the OCT may not be useful as a retinal function screening tool, being within normal limits in all eyes. Further longitudinal studies are required to determine how the relationship between ERG and OCT will evolve over time.
© 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

Entities:  

Keywords:  Asian eyes; electroretinography; myopia; optical coherence tomography

Mesh:

Year:  2014        PMID: 25331579     DOI: 10.1111/opo.12159

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  4 in total

1.  A case report of two siblings with Alstrom syndrome without hearing loss associated with two new ALMS1 variants.

Authors:  Maria F Shurygina; Maria A Parker; Catie L Schlechter; Rui Chen; Yumei Li; Richard G Weleber; Paul Yang; Mark E Pennesi
Journal:  BMC Ophthalmol       Date:  2019-12-07       Impact factor: 2.209

2.  Prediction for Cycloplegic Refractive Error in Chinese School Students: Model Development and Validation.

Authors:  Jianyong Wang; Xinyi Wang; Hans M Gao; Huiyan Zhang; Ying Yang; Fang Gu; Xin Zheng; Lei Gu; Jianyao Huang; Jia Meng; Juanjuan Li; Lei Gao; Ronghua Zhang; Jianqin Shen; Gui-Shuang Ying; Hongguang Cui
Journal:  Transl Vis Sci Technol       Date:  2022-01-03       Impact factor: 3.283

3.  Increase in b-wave amplitude after light stimulation of the blind spot is positively correlated with the axial length of myopic individuals.

Authors:  Tim Schilling; Ana Amorim-de-Sousa; Nikita A Wong; Hamed Bahmani; José Manuel González-Méijome; Paulo Fernandes
Journal:  Sci Rep       Date:  2022-03-21       Impact factor: 4.379

Review 4.  Electroretinogram responses in myopia: a review.

Authors:  Satish Kumar Gupta; Ranjay Chakraborty; Pavan Kumar Verkicharla
Journal:  Doc Ophthalmol       Date:  2021-11-17       Impact factor: 1.854

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.