Literature DB >> 25326760

Does knee revision after an articulated spacer implant provide normal gait restoration?

Nicola Logoluso1, Alice Nardo2, Federica Anasetti3, Sara Scarponi4, Carlo Luca Romanò4.   

Abstract

PURPOSE: The aim of this study was to quantitatively evaluate gait parameters in patients who underwent a revision procedure after an interval articulated spacer for septic knee prosthesis.
METHODS: Ten adult subjects underwent three-dimensional computerized gait analysis 12 months after second-stage knee revision procedure. Kinematic and kinetic parameters were acquired and compared with a normal reference population. Data were also compared with those collected in a previous study, in which the same cohort of patients underwent gait analysis 8-14 weeks after spacer implantation.
RESULTS: Kinematic and kinetic parameters did not show any significant difference between the affected and unaffected limb. Compared to normal reference population, patients treated with revision knee prosthesis showed a reduced mean gait velocity, step frequency, stride and step length, average knee range of motion, knee power and ground reaction forces. When comparing average data with those observed after spacer implant, no difference was observed in kinematic variables, while kinetic analysis demonstrated a significant improvement in knee power.
CONCLUSIONS: This study shows that 1 year after second-stage knee revision surgery, kinematic and kinetic values remain lower than those observed in a normal reference population. Only slight improvements in walking ability are shown, when analysing data in comparison with those collected after a preformed articulated knee spacer. This finding points out the long time to full functional recovery after knee revision surgery and the limited improvement of gait when compared to the one achieved at the time of spacer implant.

Entities:  

Keywords:  Gait analysis; Preformed knee articulating spacer; Revision of total knee arthroplasty; Two-stage exchange

Mesh:

Year:  2014        PMID: 25326760     DOI: 10.1007/s00167-014-3376-8

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  20 in total

Review 1.  Two-stage revision of septic knee prosthesis with articulating knee spacers yields better infection eradication rate than one-stage or two-stage revision with static spacers.

Authors:  C L Romanò; L Gala; N Logoluso; D Romanò; L Drago
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-21       Impact factor: 4.342

2.  Two-stage exchange arthroplasty using a functional antibiotic-loaded spacer in the treatment of the infected knee replacement: the Vancouver experience.

Authors:  B A Masri; R W Kendall; C P Duncan; C P Beauchamp; R W McGraw; B Bora
Journal:  Semin Arthroplasty       Date:  1994-07

3.  Intraoperative molds to create an articulating spacer for the infected knee arthroplasty.

Authors:  Geoffrey S Van Thiel; Keith R Berend; Gregg R Klein; Alexander C Gordon; Adolph V Lombardi; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

Review 4.  Static and mobile antibiotic-impregnated cement spacers for the management of prosthetic joint infection.

Authors:  Cale Jacobs; Christian P Christensen; Michael E Berend
Journal:  J Am Acad Orthop Surg       Date:  2009-06       Impact factor: 3.020

5.  Functional advantage of articulating versus static spacers in 2-stage revision for total knee arthroplasty infection.

Authors:  Mark G Freeman; Thomas K Fehring; Susan M Odum; Keith Fehring; William L Griffin; J Bohannon Mason
Journal:  J Arthroplasty       Date:  2007-12       Impact factor: 4.757

6.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

7.  Do dynamic cement-on-cement knee spacers provide better function and activity during two-stage exchange?

Authors:  David J Jaekel; Judd S Day; Gregg R Klein; Harlan Levine; Javad Parvizi; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2012-04-04       Impact factor: 4.176

8.  Patient satisfaction and outcome after septic versus aseptic revision total knee arthroplasty.

Authors:  R L Barrack; G Engh; C Rorabeck; J Sawhney; M Woolfrey
Journal:  J Arthroplasty       Date:  2000-12       Impact factor: 4.757

9.  Articulating versus static spacers in revision total knee arthroplasty for sepsis. The Ranawat Award.

Authors:  T K Fehring; S Odum; T F Calton; J B Mason
Journal:  Clin Orthop Relat Res       Date:  2000-11       Impact factor: 4.176

10.  Clinical outcome and patient satisfaction in aseptic and septic revision total knee arthroplasty.

Authors:  Ching-Jen Wang; Ming-Chun Hsieh; Ting-Wen Huang; Jun-Wen Wang; Han-Shiang Chen; Chen-Yeo Liu
Journal:  Knee       Date:  2004-02       Impact factor: 2.199

View more
  2 in total

1.  Articulated spacer provides long-term knee improvement after two-stage reimplantation.

Authors:  Michele Vasso; Chiara Del Regno; Katia Corona; Rocco D'Apolito; Alfredo Schiavone Panni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-11       Impact factor: 4.342

2.  Hot spots and trends in knee revision research since the 21st century: a bibliometric analysis.

Authors:  Kelei Zhai; Weifeng Ma; Tao Huang
Journal:  Ann Transl Med       Date:  2021-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.