In vitro biomechanical evaluation of single impulse and repetitive mechanical shockwave devices utilized for spinal manipulative therapy.

Michael A K Liebschner1, Kwonsoo Chun, Namhoon Kim, Bruce Ehni.   

Abstract

Mechanical shockwave therapy devices have been in clinical use for almost 40 years. While most often used to treat back pain, our understanding of their biomechanical performance is very limited. From biomechanical studies we know that biological tissue is viscoelastic and preferably excited around its resonance frequency. Targeting these frequencies has been the focus in extracorporeal shock wave lithotripsy, but these concepts are relatively new in orthopedic and rehabilitation therapies. The exact mechanism by which shockwave therapy acts is not known. Knowledge of the performance characteristics of these devices, correlated with clinical outcome studies, may lead to better patient selection, improvement of device functionality, and knowledge of the underlying working principals of therapy. The objectives of this study were to determine the ability of several commercial shockwave devices to achieve a desired thrust profile in a benchtop setting, determine the thrust profile in a clinical analog, and determine the influence of operator experience level on device performance. We conducted two different types of testing: (1) bench testing to evaluate the devices themselves, and (2) clinical equivalent testing to determine the influence of the operator. The results indicated a significant dependence of thrust output on the compliance of the test media. The Activator V-E device matched the ideal half-sine thrust profile to 94%, followed by the Impulse device (84%), the Activator IV/FS (74%), and the Activator II (48%). While most devices deviated from the ideal profile on the return path, the Impulse device exhibited a secondary peak. Moreover, the Activator V-E device provided evidence that the device performs consistently despite operator experience level. This has been a major concern in manual spinal manipulation. Based on our results, a hyper-flexible spine would receive a lower peak thrust force than a hypo-flexible spine at the same power setting. Furthermore, a hand-held operation further reduced the peak thrust force as it increased the system compliance. However, that influence was dissimilar for the different devices. Although controlled clinical trials are needed to determine the correlation between thrust profile and clinical outcome, already ongoing clinical studies indicate an improved patient satisfaction due to reduced treatment pain when devices are used with a thrust characteristic closer to an ideal sine wave.

Entities:  

Mesh:

Year:  2014        PMID: 25326437     DOI: 10.1007/s10439-014-1115-4

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  7 in total

1.  Characteristics of Paraspinal Muscle Spindle Response to Mechanically Assisted Spinal Manipulation: A Preliminary Report.

Authors:  William R Reed; Joel G Pickar; Randall S Sozio; Michael A K Liebschner; Joshua W Little; Maruti R Gudavalli
Journal:  J Manipulative Physiol Ther       Date:  2017-06-17       Impact factor: 1.437

2.  The profile of older adults seeking chiropractic care: a secondary analysis.

Authors:  Katie de Luca; Sheilah Hogg-Johnson; Martha Funabashi; Silvano Mior; Simon D French
Journal:  BMC Geriatr       Date:  2021-04-23       Impact factor: 3.921

3.  In vivo measurement of intradiscal pressure changes related to thrust and non-thrust spinal manipulation in an animal model: a pilot study.

Authors:  William R Reed; Michael A K Liebschner; Carla R Lima; Harshvardhan Singh; Christopher P Hurt; Daniel F Martins; James M Cox; Maruti R Gudavalli
Journal:  Chiropr Man Therap       Date:  2022-09-06

4.  Neural Response During a Mechanically Assisted Spinal Manipulation in an Animal Model: A Pilot Study.

Authors:  William R Reed; Michael A K Liebschner; Randall S Sozio; Joel G Pickar; Maruti R Gudavalli
Journal:  J Nov Physiother Phys Rehabil       Date:  2015-04-06

5.  Letter to the Editor: Cerebral Hemorrhage following Chiropractic Activator Treatment-Case Report and Review of Literature.

Authors:  Michael A K Liebschner; Bruce L Ehni
Journal:  J Neurol Surg Rep       Date:  2017-10-09

6.  Spinal Tissue Loading Created by Different Methods of Spinal Manipulative Therapy Application.

Authors:  Martha Funabashi; François Nougarou; Martin Descarreaux; Narasimha Prasad; Gregory N Kawchuk
Journal:  Spine (Phila Pa 1976)       Date:  2017-05-01       Impact factor: 3.241

7.  Beneficial effects of manually assisted chiropractic adjusting instrument in a rabbit model of osteoarthritis.

Authors:  F M Conesa-Buendía; A Mediero; R Fujikawa; P Esbrit; F Mulero; I Mahillo-Fernández; Arantxa Ortega-De Mues
Journal:  Sci Rep       Date:  2020-08-06       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.