Literature DB >> 25321134

Improved Savitzky-Golay-method-based fluorescence subtraction algorithm for rapid recovery of Raman spectra.

Kun Chen, Hongyuan Zhang, Haoyun Wei, Yan Li.   

Abstract

In this paper, we propose an improved subtraction algorithm for rapid recovery of Raman spectra that can substantially reduce the computation time. This algorithm is based on an improved Savitzky-Golay (SG) iterative smoothing method, which involves two key novel approaches: (a) the use of the Gauss-Seidel method and (b) the introduction of a relaxation factor into the iterative procedure. By applying a novel successive relaxation (SG-SR) iterative method to the relaxation factor, additional improvement in the convergence speed over the standard Savitzky-Golay procedure is realized. The proposed improved algorithm (the RIA-SG-SR algorithm), which uses SG-SR-based iteration instead of Savitzky-Golay iteration, has been optimized and validated with a mathematically simulated Raman spectrum, as well as experimentally measured Raman spectra from non-biological and biological samples. The method results in a significant reduction in computing cost while yielding consistent rejection of fluorescence and noise for spectra with low signal-to-fluorescence ratios and varied baselines. In the simulation, RIA-SG-SR achieved 1 order of magnitude improvement in iteration number and 2 orders of magnitude improvement in computation time compared with the range-independent background-subtraction algorithm (RIA). Furthermore the computation time of the experimentally measured raw Raman spectrum processing from skin tissue decreased from 6.72 to 0.094 s. In general, the processing of the SG-SR method can be conducted within dozens of milliseconds, which can provide a real-time procedure in practical situations.

Mesh:

Year:  2014        PMID: 25321134     DOI: 10.1364/AO.53.005559

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  5 in total

1.  Performance Evaluation and Implementation of FPGA Based SGSF in Smart Diagnostic Applications.

Authors:  Shivangi Agarwal; Asha Rani; Vijander Singh; A P Mittal
Journal:  J Med Syst       Date:  2015-12-15       Impact factor: 4.460

Review 2.  Clinical instrumentation and applications of Raman spectroscopy.

Authors:  Isaac Pence; Anita Mahadevan-Jansen
Journal:  Chem Soc Rev       Date:  2016-04-07       Impact factor: 54.564

3.  Weighted spectral reconstruction method for discrimination of bacterial species with low signal-to-noise ratio Raman measurements.

Authors:  Shanshan Zhu; Xiaoyu Cui; Wenbin Xu; Shuo Chen; Wei Qian
Journal:  RSC Adv       Date:  2019-03-25       Impact factor: 4.036

4.  Portable Raman Spectrometer as a Screening Tool for Characterization of Iberian Dry-Cured Ham.

Authors:  Andrés Martín-Gómez; Natalia Arroyo-Manzanares; María García-Nicolás; Ángela I López-Lorente; Soledad Cárdenas; Ignacio López-García; Pilar Viñas; Manuel Hernández-Córdoba; Lourdes Arce
Journal:  Foods       Date:  2021-05-24

5.  Collaborative Penalized Least Squares for Background Correction of Multiple Raman Spectra.

Authors:  Long Chen; Yingwen Wu; Tianjun Li; Zhuo Chen
Journal:  J Anal Methods Chem       Date:  2018-08-29       Impact factor: 2.193

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.