Literature DB >> 25315887

The value of real-time ultrasound elastography in chronic autoimmune thyroiditis.

M S Menzilcioglu1, M Duymus, G Gungor, S Citil, T Sahin, S N Boysan, A Sarica.   

Abstract

OBJECTIVE: Chronic autoimmune thyroiditis (CAT) (chronic lymphocytic thyroiditis-Hashimoto's thyroiditis), which is the most common inflammatory disorder of the thyroid gland, causes hypothyroidism. Ultrasound elastography is a newly developed sonographic technique that provides an estimation of tissue elasticity by measuring the degree of tissue displacement under the application of an external force. In this study, our aim was to evaluate the accuracy of strain index ratio with real-time ultrasound elastography and to calculate the cut-off point for the diagnosis of CAT. Our aim was also to lead further studies on other pathological changes such as lymphoma, malign nodules etc. based on CAT by using this cut-off point. The gains from this study and further studies will assist clinical diagnoses and follow-up.
METHODS: Aplio™ 500 ultrasound machine (Toshiba Medical Systems Co. Ltd, Otawara, Japan) with linear 4.8-11.0 MHz transducers and elastography software was used. Routine B-mode (dimensions and parenchymal echogenicity) ultrasound evaluation was performed prior to the ultrasound elastography.
RESULTS: A total of 31 randomized patients (3 males, 28 females) with a mean age of 39.13 ± 10.16 years (range, 16-58 years) with CAT and 21 healthy controls (6 males, 15 females) with mean age of 34.67 ± 16.31 years (range, 14-81 years) were prospectively examined. The mean values of thyroid-stimulating hormone (TSH; normal TSH value is 0.27-4.20 IU ml(-1)) and anti-thyroid peroxidase (anti-TPO; normal anti-TPO value is 0-34 IU ml(-1)) were 3.40 ± 2.70 and 373.66 ± 148.94 IU ml(-1), respectively. No correlation was detected between serum TSH and thyroid tissue strain index (Spearman r coefficient of TSH was -0.290). Positive-sided correlation was detected between anti-TPO values and thyroid tissue strain index ratio (Spearman r coefficient of anti-TPO was 0.682). The median strain index ratio of patients with CAT (1.39 ± 0.72) was significantly higher than the mean ratio of the controls (0.76 ± 0.55). The area under the receiver operating characteristic curve was 0.775 (95% confidence interval). The optimal cut-off value (in which the sum of sensitivity and specificity was highest) for the prediction of diffuse thyroid pathology was 0.677. For this cut-off ratio, thyroid stiffness had 96% sensitivity and 67% specificity. A total of 30 of 31 patients (96%) and a total of 7 of 21 healthy controls (33%) exceeded the cut-off points.
CONCLUSION: The strain index ratio was higher in CAT than in normal thyroid parenchyma in real-time ultrasound elastography. Thus, it seems to be a useful method for the assessment of CAT with real-time ultrasound elastography, and further studies assessing the correlation of sonoelastography findings and histopathological subtypes of CAT would enrich the findings of the present study. ADVANCES IN KNOWLEDGE: In our study, we detected the stiffness ratio of the thyroid tissue in patients with CAT. The cut-off value should be helpful for diagnosis or follow-up of the recently developed lesions such as lymphoma, malign nodule, etc. based on CAT. This study should also encourage new studies about CAT and ultrasound elastography.

Entities:  

Mesh:

Year:  2014        PMID: 25315887      PMCID: PMC4243205          DOI: 10.1259/bjr.20140604

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Liver fibrosis in patients with chronic hepatitis C: noninvasive diagnosis by means of real-time tissue elastography--establishment of the method for measurement.

Authors:  Yohei Koizumi; Masashi Hirooka; Yoshiyasu Kisaka; Ichiro Konishi; Masanori Abe; Hidehiro Murakami; Bunzo Matsuura; Yoichi Hiasa; Morikazu Onji
Journal:  Radiology       Date:  2011-02       Impact factor: 11.105

2.  Variations in the Elasticity of Breast Tissue During the Menstrual Cycle Determined by Real-time Sonoelastography.

Authors:  Sebastian Wojcinski; Michael Cassel; Andre Farrokh; Amr A Soliman; Ursula Hille; Werner Schmidt; Friedrich Degenhardt; Peter Hillemanns
Journal:  J Ultrasound Med       Date:  2012-01       Impact factor: 2.153

3.  ARFI elastography for the evaluation of diffuse thyroid gland pathology: Preliminary results.

Authors:  Ioan Sporea; Roxana Sirli; Simona Bota; Mihaela Vlad; Alina Popescu; Ioana Zosin
Journal:  World J Radiol       Date:  2012-04-28

Review 4.  Chronic autoimmune thyroiditis.

Authors:  C M Dayan; G H Daniels
Journal:  N Engl J Med       Date:  1996-07-11       Impact factor: 91.245

5.  Ultrasound elastographic evaluation in the diagnosis of carpal tunnel syndrome: initial findings.

Authors:  Gunes Orman; Serkan Ozben; Nergiz Huseyinoglu; Mahmut Duymus; Keziban Gunce Orman
Journal:  Ultrasound Med Biol       Date:  2013-04-30       Impact factor: 2.998

6.  Semiquantitative strain elastography of liver masses.

Authors:  Mehmet Ruhi Onur; Ahmet Kursad Poyraz; Esra Ercin Ucak; Zulkif Bozgeyik; Ibrahim Hanifi Özercan; Erkin Ogur
Journal:  J Ultrasound Med       Date:  2012-07       Impact factor: 2.153

7.  The utility of ultrasound elastography and MicroPure imaging in the differentiation of benign and malignant thyroid nodules.

Authors:  Nazan Ciledag; Kemal Arda; Bilgin Kadri Aribas; Elif Aktas; Serdal Kenan Köse
Journal:  AJR Am J Roentgenol       Date:  2012-03       Impact factor: 3.959

8.  Real-time ultrasound elastography--a noninvasive diagnostic procedure for evaluating dominant thyroid nodules.

Authors:  Christian Vorländer; Jan Wolff; Said Saalabian; Robert H Lienenlüke; Robert A Wahl
Journal:  Langenbecks Arch Surg       Date:  2010-07-15       Impact factor: 3.445

Review 9.  Inflammatory thyroid disorders.

Authors:  A P Farwell; L E Braverman
Journal:  Otolaryngol Clin North Am       Date:  1996-08       Impact factor: 3.346

10.  Differential diagnosis of benign and malignant thyroid nodules at elastosonography.

Authors:  L Rubaltelli; S Corradin; A Dorigo; M Stabilito; A Tregnaghi; S Borsato; R Stramare
Journal:  Ultraschall Med       Date:  2008-05-21       Impact factor: 6.548

View more
  14 in total

1.  Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto's thyroiditis.

Authors:  Bo-Ji Liu; Hui-Xiong Xu; Yi-Feng Zhang; Jun-Mei Xu; Dan-Dan Li; Xiao-Wan Bo; Xiao-Long Li; Le-Hang Guo; Xiao-Hong Xu; Shen Qu
Journal:  Med Oncol       Date:  2015-01-31       Impact factor: 3.064

2.  [Value of ultrasound shear wave elasticity imaging in diagnosis of Hashimoto's thyroiditis].

Authors:  Wei Wang; Hai-Ning Zheng; Qiong Wang; Yi-Xiao Han; Qing-Gui Ye; Chao-Yang Wen
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-05-20

3.  Diagnostic performance of thyroid ultrasonography screening in pediatric patients with a hypothyroid, hyperthyroid or euthyroid goiter.

Authors:  Soo Jin Lee; Gye-Yeon Lim; Jee Young Kim; Min Ho Chung
Journal:  Pediatr Radiol       Date:  2015-08-23

4.  Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules.

Authors:  Xin Sui; Huai-Jun Liu; Hong-Li Jia; Qin-Mao Fang
Journal:  Exp Ther Med       Date:  2016-05-17       Impact factor: 2.447

5.  The usefulness of strain wave elastography in the diagnosis and grading of Hashimoto's thyroiditis in children.

Authors:  Mehmet Öztürk; Ruken Yildirim
Journal:  Radiol Med       Date:  2017-08-21       Impact factor: 3.469

6.  Distinguishing benign from malignant thyroid nodules using thyroid ultrasonography: utility of adding superb microvascular imaging and elastography.

Authors:  Hye Shin Ahn; Jong Beum Lee; Mirinae Seo; Sung Hee Park; Byung Ihn Choi
Journal:  Radiol Med       Date:  2017-12-16       Impact factor: 3.469

7.  An evaluation of ocular elasticity using real-time ultrasound elastography in primary open-angle glaucoma.

Authors:  Kadir Agladioglu; Gökhan Pekel; Seher Altintas Kasikci; Ramazan Yagci; Yilmaz Kiroglu
Journal:  Br J Radiol       Date:  2016-02-03       Impact factor: 3.039

8.  Quantitative assessment of thyroid gland elasticity with shear-wave elastography in pediatric patients with Hashimoto's thyroiditis.

Authors:  Sedat Giray Kandemirli; Zuhal Bayramoglu; Emine Caliskan; Zeynep Nur Akyol Sari; Ibrahim Adaletli
Journal:  J Med Ultrason (2001)       Date:  2018-01-18       Impact factor: 1.314

Review 9.  Sonographic Elastography of the Thyroid Gland.

Authors:  Mehmet Sait Menzilcioglu; Mahmut Duymus; Serhat Avcu
Journal:  Pol J Radiol       Date:  2016-04-08

10.  Evaluation of the relationship between shear wave elastography measurements with laboratory and Doppler US parameters in patients with adult Hashimoto’s thyroiditis

Authors:  Nurten Andaç Baltacıoğlu; Ferhan Mantar; Efe Soydemir
Journal:  Turk J Med Sci       Date:  2021-04-30       Impact factor: 0.973

View more