Evaluation of Three Sources of Validity Evidence for a Synthetic Thoracoscopic Esophageal Atresia/Tracheoesophageal Fistula Repair Simulator.

Katherine A Barsness1,2, Deborah M Rooney3, Lauren M Davis4, Ellie O'Brien4.   

Abstract

PURPOSE: Thoracoscopic esophageal atresia (EA)/tracheoesophageal fistula (TEF) repair is technically challenging. We have previously reported our experiences with a high-fidelity hybrid model for simulation-based educational instruction in thoracoscopic EA/TEF, including the high cost of the tissue for these models. The purposes of this study were (1) to create a low-cost synthetic tissue EA/TEF repair simulation model and (2) to evaluate the content validity of the synthetic tissue simulator.
MATERIALS AND METHODS: Review of the literature and computed tomography images were used to create computer-aided drawings (CAD) for a synthetic, size-appropriate EA/TEF tissue insert. The inverse of the CAD image was then printed in six different sections to create a mold that could be filled with platinum-cured silicone. The silicone EA/TEF insert was then placed in a previously described neonatal thorax and covered with synthetic skin. Following institutional review board-exempt determination, 47 participants performed some or all of a simulated thoracoscopic EA/TEF during two separate international meetings (International Pediatric Endosurgery Group [IPEG] and World Federation of Associations of Pediatric Surgeons [WOFAPS]). Participants were identified as "experts," having 6-50 self-reported thoracoscopic EA/TEF repairs, and "novice," having 0-5 self-reported thoracoscopic EA/TEF repairs. Participants completed a self-report, six-domain, 24-item instrument consisting of 23 5-point rating scales and one 4-point Global Rating Scale. Validity evidence relevant to test content and response processes was evaluated using the many-facet Rasch model, and evidence of internal structure (interitem consistency) was estimated using Cronbach's alpha.
RESULTS: A review of the participants' ratings indicates there were no overall differences across sites (IPEG versus WOFAPS, P=.84) or experience (expert versus novice, P=.17). The highest observed averages were 4.4 (Value of Simulator as a Training Tool), 4.3 (Physical Attributes-chest circumference, chest depth, and intercostal space), and 4.3 (Realism of Experience-fistula location). The lowest observed averages were 3.5 (Ability to Perform-closure of fistula), 3.7 (Ability to Perform-acquisition target trocar sites), 3.8 (Physical Attributes-landmark visualization), 3.8 (Ability to Perform-anastomosis and dissection of upper pouch), and 3.9 (Realism of Materials-skin). The Global Rating Scale was 2.9, coinciding with a response of "this simulator can be considered for use in neonatal TEF repair training, but could be improved slightly." Material costs for the synthetic EA/TEF inserts were less than $2 U.S. per insert.
CONCLUSIONS: We have successfully created a low-cost synthetic EA/TEF tissue insert for use in a neonatal thoracoscopic EA/TEF repair simulator. Analysis of the participants' ratings of the synthetic EA/TEF simulation model indicates that it has value and can be used to train pediatric surgeons, especially those early in their learning curve, to begin to perform a thoracoscopic EA/TEF repair. Areas for model improvement were identified, and these areas will be the focus for future modifications to the synthetic EA/TEF repair simulator.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25314617     DOI: 10.1089/lap.2014.0370

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  5 in total

1.  The effect of forceps manipulation for expert pediatric surgeons using an endoscopic pseudo-viewpoint alternating system: the phenomenon of economical slow and fast performance in endoscopic surgery.

Authors:  Satoshi Ieiri; Takahiro Jimbo; Yuta Koreeda; Satoshi Obata; Munenori Uemura; Ryota Souzaki; Yo Kobayashi; Masakatsu G Fujie; Makoto Hashizume; Tomoaki Taguchi
Journal:  Pediatr Surg Int       Date:  2015-08-26       Impact factor: 1.827

Review 2.  Surgical applications of three-dimensional printing: a review of the current literature & how to get started.

Authors:  Don Hoang; David Perrault; Milan Stevanovic; Alidad Ghiassi
Journal:  Ann Transl Med       Date:  2016-12

3.  The Barrow Biomimetic Spine: effect of a 3-dimensional-printed spinal osteotomy model on performance of spinal osteotomies by medical students and interns.

Authors:  Michael A Bohl; James J Zhou; Michael A Mooney; Garrett J Repp; Claudio Cavallo; Peter Nakaji; Steve W Chang; Jay D Turner; U Kumar Kakarla
Journal:  J Spine Surg       Date:  2019-03

4.  Development of a posterior sagittal anorectal surgical teaching model.

Authors:  J A van Ling; G M J Bökkerink; I de Blaauw; S M B I Botden
Journal:  BMC Pediatr       Date:  2021-01-27       Impact factor: 2.125

5.  Development and validation of a novel 3D-printed simulation model for open oesophageal atresia and tracheo-oesophageal fistula repair.

Authors:  Jonathan J Neville; Carmen S Chacon; Reza Haghighi-Osgouei; Natasha Houghton; Fernando Bello; Simon A Clarke
Journal:  Pediatr Surg Int       Date:  2021-09-02       Impact factor: 1.827