Literature DB >> 25313742

Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: a dosimetric comparison.

Rajesh A Kinhikar1, Amol B Pawar, Umesh Mahantshetty, Vedang Murthy, Deepak D Dheshpande, Shyam K Shrivastava.   

Abstract

OBJECTIVE: The objective of this study was to investigate the potential role of RapidArc (RA) compared with helical tomotherapy (HT), sliding window intensity modulated radiotherapy (SW IMRT) and three-dimensional conformal radiation therapy (3D CRT) for localized prostate cancer.
MATERIALS AND METHODS: Prescription doses ranged from 60 Gy to planning target volume (PTV) and 66.25 Gy for clinical target volume prostate (CTV-P) over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI) and homogeneity index (HI). Organ sparing comparison was done with mean doses to rectum and bladder.
RESULTS: CI 95 were 1.0 ± 0.01 (RA), 0.99 ± 0.01 (HT), 0.97 ± 0.02 (IMRT), 0.98 ± 0.02 (3D CRT) for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT) for CTV-P. HI was 0.11 ± 0.03 (RA), 0.16 ± 0.08 (HT), 0.12 ± 0.03 (IMRT), 0.06 ± 0.01 (3D CRT) for PTV and 0.03 ± 0.00 (RA), 0.05 ± 0.01 (HT), 0.03 ± 0.01 (SW IMRT and 3D CRT) for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA), 24.55 ± 12.51 Gy (HT), 19.82 ± 11.61 Gy (IMRT) and 23.56 ± 12.81 Gy (3D CRT), whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA), 33.18 ± 11.12 Gy (HT, IMRT) and 38.67 ± 12.84 Gy (3D CRT).
CONCLUSION: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

Entities:  

Mesh:

Year:  2014        PMID: 25313742     DOI: 10.4103/0973-1482.138200

Source DB:  PubMed          Journal:  J Cancer Res Ther        ISSN: 1998-4138            Impact factor:   1.805


  3 in total

1.  Semi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy.

Authors:  Soheil Elmtalab; Iraj Abedi; Zahra Alirezaei; Mohammad Hossein Choopan Dastjerdi; Ghazale Geraily; Amir Hossein Karimi
Journal:  PLoS One       Date:  2022-07-29       Impact factor: 3.752

2.  Outcomes and toxicity of 313 prostate cancer patients receiving helical tomotherapy after radical prostatectomy.

Authors:  Lindsay Jensen; Bertram Yuh; Jeffrey Y C Wong; Timothy Schultheiss; Jonathan Cheng; Nora Ruel; Przemyslaw Twardowski; Sagus Sampath
Journal:  Adv Radiat Oncol       Date:  2017-08-08

3.  Cyberknife, Helical Tomotherapy and Rapid Arc SIB-SBRT Treatment Plan Comparison for Carcinoma Prostate.

Authors:  Bijina T K; Ganesh K M; Pichandi A; Muthuselvi C A
Journal:  Asian Pac J Cancer Prev       Date:  2020-04-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.