A mini-electrochemical system integrated micropipet tip and pencil graphite electrode for detection of anticancer drug sensitivity in vitro.

Xiaoling Guo1, Qian Wang2, Jinlian Li2, Jiwen Cui2, Shi Zhou2, Sue Hao3, Dongmei Wu4.   

Abstract

Developing a reliable and cost-effective miniaturized electroanalysis tool is of vital importance for cell electrochemical analysis. In this work, a novel mini-electrochemical system has been constructed for trace detection of cell samples. The mini-electrochemical system was constructed by integrating a pencil graphite modified by threonine (PT/PGE) as working electrode, an Ag/AgCl (Sat'd) as reference electrode, platinum wire as counter electrode and a micropipet tip as electrochemical cell. The mini-electrochemical system not only saved dramatically usage of samples from 500 μL in traditional electrochemical system to 10 μL, but also possessed an adjustable active surface area by changing the length of PT/PGE immersed into the cell suspension from 3mm to 15 mm, and the linear equation was ipa = 2.25 l-2.64 (R(2) = 0.990). The system was successfully used in detection of MCF-7 cells, and a nonlinear exponent relationship between peak current and the cell number range from 3.0 × l0(3) to 7.0 × l0(6) cells mL(-1) was established firstly with the index equation ipa = 59.557 e (-C/1.709)-71.486 (R(2) = 0.954). Finally, the system was used for evaluating the sensitivity of cyclophosphamide on MCF-7 cell, and the result was corresponded well with that of MTT assay. The proposed system is sufficiently simple, cheap and easy operated, and could be applied in electrochemical detection of other biological samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anticancer drug sensitivity; MCF-7 cell; Micropipet tip; Mini-electrochemical system; Pencil graphite electrode

Mesh:

Substances:

Year:  2014        PMID: 25310494     DOI: 10.1016/j.bios.2014.09.086

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Evaluation of a new lymphocyte proliferation assay based on cyclic voltammetry; an alternative method.

Authors:  Mohammad Nikbakht; Babak Pakbin; Gholamreza Nikbakht Brujeni
Journal:  Sci Rep       Date:  2019-03-14       Impact factor: 4.379

2.  Quantitative determination and toxicity evaluation of 2,4-dichlorophenol using poly(eosin Y)/hydroxylated multi-walled carbon nanotubes modified electrode.

Authors:  Xiaolin Zhu; Kexin Zhang; Chengzhi Wang; Jiunian Guan; Xing Yuan; Baikun Li
Journal:  Sci Rep       Date:  2016-12-12       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.