Literature DB >> 25310354

Endovascular treatment of complex intracranial aneurysms by pipeline flow-diverter embolization device: a single-center experience.

Fatih Keskin, Fatih Erdi, Bülent Kaya, Necdet Poyraz, Suat Keskin, Erdal Kalkan, Orhan Ozbek, Osman Koc.   

Abstract

OBJECTIVE: Endovascular coil embolization has become an effective treatment modality for most intracranial aneurysms. However, complex aneurysms including large and giant aneurysms, fusiform shaped aneurysms, wide necked aneurysm, or small aneurysm that are unsuitable for coil embolization are still deterrent to be treated. Flow diversion is a novel concept that is applied in the treatment of these complex intracranial aneurysms.
METHOD: We review the results and important features of 25 aneurysms in 24 patients who underwent endovascular treatment by using the pipeline flow-diverter embolization device. RESULT: At 6 month follow-up, all aneurysms (100%) showed total occlusion in our series. Only one patient who had giant vertebrobasilar aneurysm experienced major complication related to endovascular treatment. DISCUSSION: We suggest that parent artery reconstruction via flow diversion with the PED is a valid and safe treatment modality.

Entities:  

Keywords:  Aneurysm; Complex,; Embolization,; Endovascular,; Flow-diverter,; Pipeline,

Mesh:

Year:  2014        PMID: 25310354     DOI: 10.1179/1743132814Y.0000000450

Source DB:  PubMed          Journal:  Neurol Res        ISSN: 0161-6412            Impact factor:   2.448


  5 in total

1.  Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device.

Authors:  H Oishi; T Fujii; M Suzuki; N Takano; K Teranishi; K Yatomi; T Kitamura; M Yamamoto; S Aoki; H Arai
Journal:  AJNR Am J Neuroradiol       Date:  2019-05-02       Impact factor: 3.825

2.  Meta-Analysis of the Efficiency and Prognosis of Intracranial Aneurysm Treated with Flow Diverter Devices.

Authors:  Gengfan Ye; Meng Zhang; Lin Deng; Xiaohui Chen; Yunyan Wang
Journal:  J Mol Neurosci       Date:  2016-01-27       Impact factor: 3.444

3.  Complex cerebral aneurysms: intra-luminal reconstruction using Pipeline flow-diverting stent and the obliteration mechanism.

Authors:  Xianli Lv; Chuhan Jiang; Zhongxue Wu; Weijian Jiang; Guihuai Wang
Journal:  Neuroradiol J       Date:  2019-12-11

4.  Inadvertent Complication of a Pipeline Embolization Device for Treatment with Vertebral Artery Dissecting Aneurysm : Distal Tip Fracture of Delivery Wire.

Authors:  Jung Soo Park; Hyo Sung Kwak; Jong Myong Lee
Journal:  J Korean Neurosurg Soc       Date:  2016-09-08

5.  Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model.

Authors:  Gaurav Girdhar; Arielle Andersen; Elizabeth Pangerl; Reza Jahanbekam; Samantha Ubl; Kevin Nguyen; John Wainwright; Michael F Wolf
Journal:  J Biomed Mater Res A       Date:  2018-09-22       Impact factor: 4.396

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.