Prospective Comparison of One-Piece and Three-Piece Tecnis Aspheric Intraocular Lenses: 1-year Stability and its Effect on Visual Function.

Kazunori Miyata1, Yasushi Kataoka, Jiro Matsunaga, Masato Honbo, Keiichiro Minami.   

Abstract

PURPOSE: To compare the stability and visual function of one-piece hydrophobic intraocular lens (IOL) (ZCB00, Abbot Medical Optics) and a three-piece hydrophobic IOL (ZA9003, Abbot Medical Optics) after cataract surgery.
MATERIALS AND METHODS: Eighteen eyes of 18 patients with the one-piece IOL and 20 eyes of 20 patients with the three-piece IOL who underwent cataract surgery were evaluated prospectively on best corrected distance visual acuity, postoperative refractive error, IOL decentration and tilt, anterior chamber depth (ACD), spherical aberration and contrast sensitivity. Measurements were performed 1 week and 1, 3, 6 and 12 months postoperatively. The postoperative outcomes were compared between the two groups.
RESULTS: In the one-piece group, a hyperopic refractive error (p < 0.002) and deeper ACDs during 1-year post-operatively were observed compared with the three-piece group. There were no significant differences in BCVA, IOL tilt, spherical aberration or contrast sensitivity.
CONCLUSIONS: The stability of the one-piece IOL was greater than that of the three-piece IOL. The postoperative ACD and refractive error demonstrated that an anteriorly offset haptic in the one-piece IOL allowed incremental fixation to the posterior capsule.

Entities:  

Keywords:  Anterior chamber depth; IOL stability; lens haptic; one-piece intraocular lens; posterior capsule

Mesh:

Year:  2014        PMID: 25310136     DOI: 10.3109/02713683.2014.968936

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  4 in total

1.  Refractive Changes Following Premature Posterior Capsulotomy Using Neodymium:Yttrium-Aluminum-Garnet Laser.

Authors:  Chia-Yi Lee; Tsai-Te Lu; Yaa-Jyuhn James Meir; Kuan-Jen Chen; Chun-Fu Liu; Chao-Min Cheng; Hung-Chi Chen
Journal:  J Pers Med       Date:  2022-02-13

2.  Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction.

Authors:  So Goto; Naoyuki Maeda; Kazuhiko Ohnuma; Toru Noda
Journal:  PLoS One       Date:  2022-08-30       Impact factor: 3.752

3.  Comparison of Two Toric IOLs with Different Haptic Design: Optical Quality after 1 Year.

Authors:  Kata Miháltz; Michael Lasta; Michael Burgmüller; Pia Veronika Vécsei-Marlovits; Birgit Weingessel
Journal:  J Ophthalmol       Date:  2018-02-11       Impact factor: 1.909

4.  Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system.

Authors:  Kazuno Negishi; Sachiko Masui; Hidemasa Torii; Yasuyo Nishi; Kazuo Tsubota
Journal:  PLoS One       Date:  2020-09-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.