Literature DB >> 25308741

Silane-modified surfaces in specific antibody-mediated cell recognition.

Karolina Sterzynska1, Joanna Budna, Emilia Frydrych-Tomczak, Grzegorz Hreczycho, Agnieszka Malinska, Hieronim Maciejewski, Maciej Zabel.   

Abstract

The immobilization of antibodies on various surfaces has been the subject of advanced research in various immunoassay-based diagnostic devices. The physical and chemical stabilities of the immobilized antibodies on a solid surface still cause many problems because upon immobilizing antibody molecules, the antigen-binding ability usually decreases. The silanization of surfaces with organosilanes carrying chemically active groups such as (3-aminopropyl) triethoxysilane (APTES) can accommodate these antigen-binding molecules in an appropriate orientation so that their functionality and binding activity are essentially retained. In this study, n-butyltrimethoxysilane (BMS) and 3-(octafluoropentyloxy)-propyltriethoxysilane (OFPOS) were used as "blocking silanes". The aims of this study were to compare the effectiveness of specific antibody binding of APTES, APTES + BMS and APTES + OFPOS and to characterize the modified surfaces by contact angle measurements and immunofluorescence measurements prior to and after immobilizing proteins. Additionally, we have evaluated the functionality of the immobilized antibodies by their abilities to bind EpCAM-positive human colon adenocarcinoma cell line (LoVo) and EpCAM-negative mouse embryonic fibroblast cell line (3T3). Cell enumeration was conducted on the basis of DAPI-positive signals and recorded using a confocal laser scanning biological microscope. The results of our study showed that the immobilization capability and reactivity of APTES, APTES + BMS and APTES + OFPOS differ. The modification of APTES with unreactive silanes (BMS,OFPOS) is recommended to improve the antibody binding efficiency. However, using OFPOS resulted in more effective antibody and cell binding, and it appears to be the most useful compound in specific antibody-mediated cell recognition.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25308741     DOI: 10.5603/FHC.2014.0029

Source DB:  PubMed          Journal:  Folia Histochem Cytobiol        ISSN: 0239-8508            Impact factor:   1.698


  3 in total

1.  Development and evaluation of an IgY based silica matrix immunoassay platform for rapid onsite SEB detection.

Authors:  J Achuth; R M Renuka; K Jalarama Reddy; M S Shivakiran; M Venkataramana; K Kadirvelu
Journal:  RSC Adv       Date:  2018-07-16       Impact factor: 4.036

2.  Optical Fiber Gratings Immunoassays.

Authors:  Médéric Loyez; Maxime Lobry; Ruddy Wattiez; Christophe Caucheteur
Journal:  Sensors (Basel)       Date:  2019-06-07       Impact factor: 3.576

3.  Cytokeratins Biosensing Using Tilted Fiber Gratings.

Authors:  Médéric Loyez; Jacques Albert; Christophe Caucheteur; Ruddy Wattiez
Journal:  Biosensors (Basel)       Date:  2018-08-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.