Literature DB >> 25304707

Multi-national findings on radiation protection of children.

Madan M Rehani1.   

Abstract

This article reviews issues of radiation protection in children in 52 low-resource countries. Extensive information was obtained through a survey by the International Atomic Energy Agency (IAEA); wide-ranging information was available from 40 countries and data from the other countries pertained to frequency of pediatric CT examinations. Of note is that multi-detector CT (MDCT) was available in 77% of responses to the survey, typically nodal centers in these countries. Nearly 75% of these scanners were reported to have dose displays. The pediatric CT usage was lower in European facilities as compared to Asian and African facilities, where usage was twice as high. The most frequently scanned body part was the head. Frequent use of 120 kVp was reported in children. The ratio of maximum to minimum CT dose index volume (CTDIvol) values varied between 15 for abdomen CT in the age group 5-10 years and 100 for chest CT in the age group <1 year. In 8% of the CT systems, CTDI values for pediatric patients were higher than those for adults in at least one age group and for one type of examination. Use of adult protocols for children was associated with CTDIw or CTDIvol values in children that were double those of adults for head and chest examination and 50% higher for abdomen examination. Patient dose records were kept in nearly half of the facilities, with the highest frequency in Europe (55% of participating facilities), and in 49% of Asian, 36% of Latin American and 14% of African facilities. The analysis of the first-choice examinations in seven clinical conditions showed that practice was in accordance with guidelines for only three of seven specified clinical conditions.

Entities:  

Mesh:

Year:  2014        PMID: 25304707     DOI: 10.1007/s00247-014-3125-7

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  3 in total

1.  IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols.

Authors:  Jenia Vassileva; Madan M Rehani; Kimberly Applegate; Nada A Ahmed; Humoud Al-Dhuhli; Huda M Al-Naemi; Jamila Salem Al Suwaidi; Danijela Arandjic; Adnan Beganovic; Tony Benavente; Simone Dias; Leila El-Nachef; Dario Faj; Mirtha E Gamarra-Sánchez; Juan Garcia Aguilar; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanovic; Arif Jauhari; Mohammad Hassan Kharita; Siarhei Kharuzhyk; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Desislava Kostova-Lefterova; Ivana Kralik; Lantao Liu; Jolanta Mazuoliene; Patricia Mora; Wilbroad Muhogora; Pirunthavany Muthuvelu; Denisa Nikodemova; Leos Novak; Aruna S Pallewatte; Mohamed Shaaban; Esti Shelly; Karapet Stepanyan; Eu-Leong Harvey J Teo; Naw Thelsy; Pannee Visrutaratna; Areesha Zaman; Dejan Zontar
Journal:  Eur Radiol       Date:  2012-09-01       Impact factor: 5.315

2.  Paediatric CT examinations in 19 developing countries: frequency and radiation dose.

Authors:  W E Muhogora; N A Ahmed; J S Alsuwaidi; A Beganovic; O Ciraj-Bjelac; V Gershan; E Gershkevitsh; E Grupetta; M H Kharita; N Manatrakul; B Maroufi; M Milakovic; K Ohno; L Ben Omrane; J Ptacek; C Schandorf; M S Shaaban; N Toutaoui; D Sakkas; J S Wambani; M M Rehani
Journal:  Radiat Prot Dosimetry       Date:  2010-02-11       Impact factor: 0.972

3.  IAEA survey of pediatric CT practice in 40 countries in Asia, Europe, Latin America, and Africa: Part 1, frequency and appropriateness.

Authors:  Jenia Vassileva; Madan M Rehani; Humoud Al-Dhuhli; Huda M Al-Naemi; Jamila Salem Al-Suwaidi; Kimberly Appelgate; Danijela Arandjic; Einas Hamed Osman Bashier; Adnan Beganovic; Tony Benavente; Tadeusz Bieganski; Simone Dias; Leila El-Nachef; Dario Faj; Mirtha E Gamarra-Sánchez; Juan Garcia-Aguilar; L'ubka Gbelcová; Vesna Gershan; Eduard Gershkevitsh; Edward Gruppetta; Alexandru Hustuc; Sonja Ivanovic; Arif Jauhari; Mohammad Hassan Kharita; Siarhei Kharuzhyk; Nadia Khelassi-Toutaoui; Hamid Reza Khosravi; Helen Khoury; Desislava Kostova-Lefterova; Ivana Kralik; Lantao Liu; Jolanta Mazuoliene; Patricia Mora; Wilbroad Muhogora; Pirunthavany Muthuvelu; Leos Novak; Aruna S Pallewatte; Mohamed Shaaban; Esti Shelly; Karapet Stepanyan; Eu-Leong Harvey J Teo; Naw Thelsy; Pannee Visrutaratna; Areesha Zaman; Dejan Zontar
Journal:  AJR Am J Roentgenol       Date:  2012-05       Impact factor: 3.959

  3 in total
  2 in total

Review 1.  Review of the current status of radiation protection in diagnostic radiology in Africa.

Authors:  Wilbroad Muhogora; Madan M Rehani
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-12

2.  Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study.

Authors:  Atul M Padole; Pallavi Sagar; Sjirk J Westra; Ruth Lim; Katherine Nimkin; Mannudeep K Kalra; Michael S Gee; Madan M Rehani
Journal:  Insights Imaging       Date:  2019-09-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.