Literature DB >> 25300890

Point-based superimposition of a digital dental model on to a three-dimensional computed tomographic skull: an accuracy study in vitro.

X Lin1, T Chen2, J Liu2, T Jiang2, D Yu2, S G F Shen3.   

Abstract

We investigated the accuracy of point-based superimposition of a digital dental model on to a 3-dimensional computed tomographic (CT) skull with intact dentition. The physical model was scanned by CT to give a virtual skull model, and a plaster dental model was taken and laser-scanned to give a digital dental model. Three different background investigators were recruited and calibrated to make the point-based superimposition, and afterwards were asked to repeat 5 superimpositions each. Five bone-to-tooth measurements for the maxilla and 6 for the mandible were selected to indicate the relation of teeth to skull. Repeated measures were made on the physical model to act as a control group, and on the virtual model to act as the test group. The absolute agreement intra-class correlation coefficient (ICC) was used to assess the intra/inter-investigator reliability; Bland-Altman analysis was used to calculate the general differences, limits of agreement, and precision ranges of the estimated limits. Inter/intra-investigator reliability was excellent with ICC varying from 0.986 to 1; Bland-Altman analysis indicated that general difference was 0.01 (0.25)mm, the upper limit of agreement was 0.50mm and the lower limit -0.47 mm, and the precision range for the upper limit was 0.43 mm to 0.57 mm and for the lower limit -0.54 mm to -0.40 mm. Clinically acceptable accuracy can be achieved using a direct point-based method to superimpose a digital dental model on to a 3-dimensional CT skull.
Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Keywords:  Bland–Altman analysis; Computer-aided orthognathic surgery; Image fusion; Point-based superimposition; Three-dimensional planning

Mesh:

Year:  2014        PMID: 25300890     DOI: 10.1016/j.bjoms.2014.09.007

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  6 in total

Review 1.  Orthognathic Surgery: A Review of Articles Published in 2014-2015.

Authors:  Vaibhav Singh; K N V Sudhakar; Rajat Mohanty; Suravi Chatterjee
Journal:  J Maxillofac Oral Surg       Date:  2016-12-17

2.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

3.  In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration.

Authors:  Gaofeng Han; Jing Li; Shuo Wang; Yan Liu; Xuedong Wang; Yanheng Zhou
Journal:  Korean J Orthod       Date:  2019-03-19       Impact factor: 1.372

4.  Efficacy of Constructing Digital Hybrid Skull-Dentition Images Using an Intraoral Scanner and Cone-Beam Computed Tomography.

Authors:  Joo-Hee Lee; Soo-Hwan Byun; Sang-Min Yi; In-Young Park; Byoung-Eun Yang; Hye-Lim Lee
Journal:  Scanning       Date:  2022-03-03       Impact factor: 1.932

5.  Integrating maxillary dentition and 3D facial photo using a modified CAD/CAM facebow.

Authors:  Peiqi Wang; Hui Xu; Rui Gu; Liwei Zhu; Ding Bai; Chaoran Xue
Journal:  BMC Oral Health       Date:  2022-08-26       Impact factor: 3.747

6.  Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography.

Authors:  Hai Yen Mai; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2020-08-04       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.