Literature DB >> 25299399

Aortic elastic properties predict occult coronary artery disease: a multidetector row computed tomography study.

Emre Gürel1, Kursat Tigen, Tansu Karaahmet, Cetin Gecmen, Bulent Mutlu, Mustafa Bulut, Yelda Basaran.   

Abstract

BACKGROUND: Multidetector row computed tomography (MDCT) is an attractive noninvasive imaging modality to detect coronary atherosclerotic plaques which may be underestimated by conventional angiography. However, its routine clinical use is limited due to contrast-associated problems, high cost, inapplicability at bedside and exposure to radiation. Thus, exploring safer and more practical measurements to predict occult coronary artery disease (CAD) is required. AIM: To demonstrate the predictive value of aortic elastic properties for occult CAD diagnosed by MDCT.
METHODS: Forty subjects with angiographically normal coronary arteries were consecutively included in our study. They underwent MDCT including indications and were divided into a no CAD group (23 subjects, 11 males, 46 ± 8 years) and an occult CAD group (17 subjects, 12 males, 48 ± 10 years), with respect to the presence of coronary plaque. As a control group, 19 consecutive patients with angiographically proven CAD (16 males, 52 ± 6 years) were included. Aortic stiffness index (ASI), aortic distensibility and aortic strain were calculated from the aortic diameters measured by echocardiography and blood pressure obtained by sphygmomanometry.
RESULTS: It was found that ASI, aortic distensibility and aortic strain were significantly different in the occult CAD group compared to the no CAD group (p = 0.008, p = 0.01, p = 0.03, respectively) and to the evident CAD group (p = 0.01, p = 0.02, p = 0.02). They also differed significantly between the no CAD and the evident CAD groups. Receiver operating characteristics analysis for ASI, to distinguish between the occult CAD group and the no CAD group, revealed an area under the curve of 0.80 (confidence interval 0.68-0.94, p = 0.004) and that the cut-off value of 3.42 could significantly predict patients with occult CAD (sensitivity: 78%; specificity: 63%).
CONCLUSIONS: Measurement of ASI is an easily applicable and safe method with its non-radiographic ability for the assessment of aortic stiffness, and it may be useful to predict subclinical atherosclerosis in clinical practice. A cut-off value of 3.42 for ASI may guide to refer individuals to preventive strategies to reduce atherosclerosis progression.

Entities:  

Mesh:

Year:  2014        PMID: 25299399     DOI: 10.5603/KP.a2014.0188

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  1 in total

1.  Aortic propagation velocity does not correlate with classical aortic stiffness parameters in healthy individuals.

Authors:  Hatem Arı; Fatih Kahraman; Yasin Türker; Serdar Güler; Hasan Aydın Baş; Doğan Erdoğan
Journal:  Anatol J Cardiol       Date:  2017-10-30       Impact factor: 1.596

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.