Literature DB >> 25298635

An Evaluation of the Point-of-Care Analyzer, i-Smart 30, for Measurement of Electrolytes.

Subhash C Arya1, Nirmala Agarwal1, Beena Michael1.   

Abstract

Analytical functioning of a point-of-care analyzer, i-Smart 30 (i-sens: Seoul, South Korea), for electrolyte quantification was investigated at Sant Parmanand Hospital, a tertiary-care hospital in Delhi, India. Samples that were received for electrolyte assay were assayed, double-blinded for their Na and K level using the arterial blood gas analyzer, the ABL 555 (Radiometer, Copenhagen) and the i-Smart 30 electrolyte analyzer. There was satisfactory correlation between the results obtained with the two analyzers with an encouraging bias, standard deviation and the 95 % limits of agreement between the data generated for Na and K levels. The performance of the i-Smart 30 would be satisfactory during the point-of-care measurements of Na and K levels in emergency rooms and clinical laboratories with inadequate infrastructure only if its day-to-day performance was monitored to ensure reliability of the generated reports.

Entities:  

Keywords:  Electrolytes; Emergency investigations; Field studies; Laboratory infrastructure; Point-of-care assays

Year:  2013        PMID: 25298635      PMCID: PMC4175705          DOI: 10.1007/s12291-013-0403-3

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  4 in total

1.  External quality assessment of clinical biochemical assays in a medium non-academic, non-research hospital laboratory.

Authors:  Subhash C Arya; Nirmala Agarwal; Shekhar Agarwal; Beena Michael
Journal:  Saudi Med J       Date:  2011-01       Impact factor: 1.484

2.  Evaluation of automated blood count analyzers for utility in resource poor laboratories.

Authors:  Subhash C Arya; Nirmala Agarwal
Journal:  Clin Chim Acta       Date:  2008-11-24       Impact factor: 3.786

3.  The operation, quality and costs of a district hospital laboratory service in Malawi.

Authors:  C J F Mundy; I Bates; W Nkhoma; K Floyd; G Kadewele; M Ngwira; A Khuwi; S B Squire; C F Gilks
Journal:  Trans R Soc Trop Med Hyg       Date:  2003 Jul-Aug       Impact factor: 2.184

4.  Laboratory systems and services are critical in global health: time to end the neglect?

Authors:  John N Nkengasong; Peter Nsubuga; Okey Nwanyanwu; Guy-Michel Gershy-Damet; Giorgio Roscigno; Marc Bulterys; Barry Schoub; Kevin M DeCock; Deborah Birx
Journal:  Am J Clin Pathol       Date:  2010-09       Impact factor: 2.493

  4 in total
  1 in total

1.  Performance evaluation of the i-Smart 300E cartridge for point-of-care electrolyte measurement in serum and plasma.

Authors:  Beomki Lee; Hyung-Doo Park
Journal:  J Clin Lab Anal       Date:  2022-02-14       Impact factor: 2.352

  1 in total