Juliana Pereira Machado1, Eugenia Velludo Veiga1, Paulo Alexandre Camargo Ferreira2, José Carlos Amado Martins2, Ana Carolina Queiroz Godoy Daniel3, Amanda dos Santos Oliveira1, Patrícia Costa Dos Santos da Silva1.
Abstract
OBJECTIVE: To determine and to analyze the theoretical and practical knowledge of Nursing professionals on indirect blood pressure measurement.Entities:
Mesh:
Year: 2014 PMID: 25295455 PMCID: PMC4872945 DOI: 10.1590/s1679-45082014ao2984
Source DB: PubMed Journal: Einstein (Sao Paulo) ISSN: 1679-4508
Frequency of correct answers on preparation of patients and environment for blood pressure measurement among Nursing professionals of the coronary unit
| Measurement step | Theoretical assessment n (%) | Practical assessment n (%) |
|---|---|---|
| Preparation of patient and environment | ||
| Full bladder was checked | 23 (74.2) | 19 (61.3) |
| Physical exercises within, 60 minutes before measurement was checked | 28 (90.3) | 18 (58.1) |
| Consumption of alcohol within 30 minutes before consultation was checked | 5 (16.1) | 4 (12.9) |
| Consumption of coffee/food within 30 minutes before consultation was checked | 8 (25.8) | 8 (25.8) |
| Smoking within 30 minutes before consultation was checked | 14 (45.2) | 11 (35.5) |
| Resting of at least 5 minutes before measurement was authorized | 4 (12.9) | 26 (83.9) |
| A quiet and calm environment was provided | 27 (87.1) | 14 (45.2) |
| Patient was informed to refrain from talking while BP was measured | 16 (51.6) | 1 (3.2) |
| Patient was quiet during the procedure | 6 (19.4) | 29 (93.5) |
| BP: blood pressure. | ||
Frequency of correct answers on patient’s position for blood pressure measurement among Nursing professionals of the coronary unit
| Measurement step | Theoretical assessment n (%) | Practical assessment n (%) |
|---|---|---|
| Patient’s position | ||
| Patient’s arm was positioned at heart level | 23 (74.2) | 26 (83.9) |
| Patient maintained his/her arm supported on a firm surface | 10 (32.3) | 28 (90.3) |
| Patient’s elbow was slightly flexed | 4 (12.9) | 28 (90.3) |
| Patient’s hand palm was held up | 5 (12.9) | 27 (87.1) |
| Patient was asked to remove some clothes for cuff placement | 1 (3.2) | 24 (77.4) |
| Patient kept his/her legs uncrossed | 22 (71.0) | 24 (77.4) |
Frequency of correct answers on care with device for blood pressure measurement among Nursing professionals of the coronary unit
| Measurement step | Theoretical assessment n (%) | Practical assessment n (%) |
|---|---|---|
| Care with the device | ||
| Deadline for device calibration date was checked | 13 (58.1) | 5 (16.1) |
| Patients’ arm circumference was measured | 18 (58.1) | 5 (16.1) |
| Cuff was selected based on arm size | 1 (3.2) | 8 (25.8) |
| Cuff was placed without looseness | 3 (9.7) | 28 (90.3) |
| Cuff was placed 2-3 cm above the antecubital fossa | 14 (45.2) | 25 (80.6) |
| Center of cuff was centered over brachial artery | 15 (48.4) | 15 (48.4) |
| Inadequate use of cuff can influence values | 30 (96.8) | - |
Frequency of correct answers obtained and recorded concerning values for blood pressure measurement among nursing professionals of the coronary unit
| Measurement step | Theoretical assessment n (%) | Practical assessment n (%) |
|---|---|---|
| Obtained and recorded values | ||
| Patient waited for 1 minute to next measurement | 8 (25.8) | 11 (35.5) |
| Inflated up to 20-30mmHg above estimated systolic blood pressure | 18 (58.1) | 27 (87.1) |
| Systolic blood pressure was determined using auscultation of 1st song (Korotkoff phase I) | 21 (67.7) | 31 (100.0) |
| Professional recorded blood pressure values without rounding values | 9 (29.0) | 7 (22.6) |
| Record of arm used for blood pressure | 30 (96.8) | 3 (9.7) |
| Record of blood pressure values in mmHg | 30 (96.8) | 30 (96.8) |
| Notes made directly on patient’s chart | - | 29 (93.5) |
Frequência de respostas corretas sobre o preparo do cliente e ambiente para a medida da pressão arterial, entre profissionais de Enfermagem de uma unidade coronariana
| Etapa da medida | Avaliação teórica | Avaliação prática |
|---|---|---|
| n (%) | n (%) | |
| Preparo do cliente e do ambiente | ||
| Checou bexiga cheia | 23 (74,2) | 19 (61,3) |
| Checou exercícios físicos 60 minutos antes | 28 (90,3) | 18 (58,1) |
| Checou ingestão bebidas alcoólicas 30 minutos antes | 5 (16,1) | 4 (12,9) |
| Checou ingestão de café/alimentos 30 minutos antes | 8 (25,8) | 8 (25,8) |
| Checou consumo de tabaco 30 minutos antes | 14 (45,2) | 11 (35,5) |
| Permitiu repouso de pelo menos 5 minutos | 4 (12,9) | 26 (83,9) |
| Proporcionou ambiente calmo e silencioso | 27 (87,1) | 14 (45,2) |
| Orientou o cliente para não conversar | 16 (51,6) | 1 (3,2) |
| Manteve-se em silêncio durante o procedimento | 6 (19,4) | 29 (93,5) |
Frequência de respostas corretas sobre a posição do cliente para a medida da pressão arterial, entre profissionais de Enfermagem de uma unidade coronariana
| Etapa da medida | Avaliação teórica | Avaliação prática |
|---|---|---|
| n (%) | n (%) | |
| Posição do cliente | ||
| Posicionou o braço do cliente na altura do coração | 23 (74,2) | 26 (83,9) |
| Manteve o braço do cliente apoiado | 10 (32,3) | 28 (90,3) |
| Manteve o cotovelo levemente fletido | 4 (12,9) | 28 (90,3) |
| Manteve palma da mão voltada para cima | 5 (12,9) | 27 (87,1) |
| Removeu roupas para colocar manguito | 1 (3,2) | 24 (77,4) |
| Manteve pernas do cliente descruzadas | 22 (71,0) | 24 (77,4) |
Frequência de respostas corretas sobre os cuidados com o aparelho para a medida da pressão arterial, entre profissionais de Enfermagem de uma unidade coronariana
| Etapa da medida | Avaliação teórica | Avaliação prática |
|---|---|---|
| n (%) | n (%) | |
| Cuidados com o aparelho | ||
| Checou o prazo de calibração do aparelho | 13 (58,1) | 5 (16,1) |
| Mediu a circunferência do braço do cliente | 18 (58,1) | 5 (16,1) |
| Selecionou o manguito de tamanho ideal ao braço | 1 (3,2) | 8 (25,8) |
| Colocou o manguito sem deixar folgas | 3 (9,7) | 28 (90,3) |
| Colocou o manguito 2-3 acima da fossa anticubital | 14 (45,2) | 25 (80,6) |
| Centralizou o meio do manguito sobre a artéria braquial | 15 (48,4) | 15 (48,4) |
| Concordou que usar manguito inadequado pode influenciar valores | 30 (96,8) | - |
Frequência de respostas corretas sobre a obtenção e o registro dos valores para a medida da pressão arterial, entre profissionais de Enfermagem de uma unidade coronariana
| Etapa da medida | Avaliação teórica | Avaliação prática |
|---|---|---|
| n (%) | n (%) | |
| Obtenção e registro dos valores | ||
| Aguardou 1 minuto para a próxima medida | 8 (25,8) | 11 (35,5) |
| Inflou até 20-30mmHg acima da pressão arterial sistólica estimada | 18 (58,1) | 27 (87,1) |
| Determinou pressão arterial sistólica na ausculta do primeiro som (fase I Korotkoff) | 21 (67,7) | 31 (100,0) |
| Anotou os valores da pressão arterial sem arredondamentos | 9 (29,0) | 7 (22,6) |
| Anotou o membro em que foi verificada a pressão arterial | 30 (96,8) | 3 (9,7) |
| Registrou valores de pressão arterial, em mmHg | 30 (96,8) | 30 (96,8) |
| Realizou anotação diretamente no prontuário | - | 29 (93,5) |