INTRODUCTION: Thromboembolic complications contribute substantially to perioperative morbidity and mortality. Routine laboratory tests do not detect patients with acquired or congenital hypercoagulability who may be at increased risk of perioperative thromboembolism. Rotational thromboelastometry (ROTEM) is a digitized modification of conventional thromboelastography that is stable and technically easy to use. We designed a prospective observational study to evaluate whether preoperative ROTEM can identify patients at increased risk for postoperative thromboembolic complications after major non-cardiac surgery.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25292221 PMCID: PMC4200117 DOI: 10.1186/s13054-014-0549-2
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Preoperative rotational thromboelastometry (ROTEM) parameters
|
|
|
|
|
|
|
|---|---|---|---|---|---|
|
| |||||
| Clotting time, s | 42 to 74 | 55.1 (31.2) | 48.7 (16.9) | 0.19 | --- |
| Clot formation time, s | 46 to 148 | 87.1 (61.7) | 58.5 (16.6) | <0.001 | 0.74 |
| Alpha angle, degrees | 63 to 81 | 74.3 (6.9) | 78.4 (3.1) | 0.002 | 0.70 |
| Amplitude at 10/20 minutes, mm | 50 to 69 | 58.2 (8.7) | 64.0 (5.4) | 0.008 | 0.72 |
| Maximum clot firmness, mm | 49 to 71 | 65.0 (7.5) | 70.4 (5.2) | 0.009 | 0.73 |
|
| |||||
| Clotting time, s | 137 to 246 | 171.5 (34.1) | 165.8 (24.6) | 0.11 | --- |
| Clot formation time, s | 71 to 82 | 72.2 (57.3) | 51.0 (11.4) | <0.001 | 0.75 |
| Alpha angle, degrees | 52 to 72 | 76.5 (5.5) | 79.4 (2.4) | 0.006 | 0.72 |
| Amplitude at 10/20 minutes, mm | 137 to 246 | 56.7 (7.8) | 63.0 (5.8) | 0.012 | 0.75 |
| Maximum clot firmness, mm | 52 to 72 | 62.8 (7.1) | 68.6 (6.0) | 0.02 | 0.74 |
|
| |||||
| Clotting time, s | 43 to 69 | 53.3 (47.4) | 44.7 (13.1) | 0.11 | --- |
| Clot formation time, s | 339.9 (366.5) | 378.9 (606.0) | 0.12 | --- | |
| Alpha angle, degrees | 73.6 (6.6) | 77.0 (5.4) | 0.085 | --- | |
| Amplitude at 10/20 minutes, mm | 8 to 21 | 16.5 (6.8) | 23.7 (11.2) | 0.010 | --- |
| Maximum clot firmness, mm | 9 to 25 | 17.8 (7.6) | 24.8 (11.2) | 0.015 | --- |
For significant predictive tests, the area under the curve (AUC) of the receiver operating characteristic (ROC) curve is listed. EXTEM, extrinsic rotational thromboelastometry; INTEM, intrinsic rotational thromboelastometry; FIBTEM, fibrinogen rotational thromboelastometry; ns, not significant.
Patient demographics, outcomes and standard coagulation studies
|
|
|
|
| |
|---|---|---|---|---|
| Age, years | 58.7 (+/−15.2) | 58.5 (+/−15.2) | 63.6 (+/−16.1) | 0.30 |
| Body mass index, kg/m2 | 27.7 (+/−6.3) | 27.8 (+/−6.3) | 26.4 (+/−4.8) | 0.49 |
| Obesity | 102 (32.6%) | 99 (32.7%) | 3 (30%) | 0.57 |
| Female | 165 (53%) | 161 (53%) | 4 (40%) | 0.88 |
|
| ||||
| Major abdominal | 85 (27%) | 81 (27%) | 4 (40%) | 0.47 |
| Gynecological | 4 (1%) | 4 (1%) | 0 (0%) | 1.0 |
| Central nervous system neurosurgery | 48 (15%) | 48 (16%) | 0 (0% | 0.37 |
| Spine | 62 (20%) | 60 (20%) | 2 (20%) | 1.0 |
| Vascular | 11 (4%) | 11 (4%) | 0 (0%) | 1.0 |
| Urology | 26 (8%) | 23 (8%) | 3 (30%) | 0.04 |
| Orthopedics | 29 (9%) | 29 (10%) | 0 (0%) | 0.60 |
| Liver surgery | 20 (6%) | 19 (6%) | 1 (10%) | 0.49 |
| Renal transplant | 24 (8%) | 24 (8%) | 0 (0%) | 1.0 |
| Other | 4 (1%) | 4 (1%) | 0 (0%) | 1.0 |
| Cancer | 147 (47.0%) | 141 (46.5%) | 6 (60%) | 0.62 |
| End-stage renal disease | 17 (5.4%) | 17 (5.6%) | 0 (0%) | 1.0 |
|
| ||||
| ICU length of stay, days | 1.1 (+/−3.8) | 0.9 (+/−3.4) | 5.7 (+/−9.7) | 0.15 |
| Hospital length of stay, days | 6.8 (+/−10.1) | 6.2 (+/−7.8) | 25.5 (+/−32.4) | 0.09 |
| Myocardial infarction | 3 (1%) | 3 (1%) | 0 (0%) | 1.0 |
| Acute kidney injury (RIFLE-risk) | 12 (3.8%) | 12 (3.9%) | 0 (0%) | 1.0 |
|
| ||||
| Prothrombin time, s | 32.3 (+/−11.6) | 32.3 (+/−11.8) | 33.1 (+/−6.2) | 0.89 |
| International normalized ratio | 1.20 (+/−0.24) | 1.20 (+/−0.25) | 1.28 (+/−0.11) | 0.39 |
| Platelet count | 201 (+/−67) | 201 (+/−68) | 212 (+/−69) | 0.63 |
Data are reported as mean and standard deviation or number and percentage, as appropriate. Obesity = body mass index >30 m/kg2. RIFLE, risk, injury, failure, loss, end-stage renal failure; ns = not significant.
Figure 1Preoperative rotational thromboelastometry (ROTEM) parameters using extrinsic rotational thromboelastometry (EXTEM) and intrinsic rotational thromboelastometry (INTEM) activators in patients with and without thromboembolic complications (TEC). Ex-CT, EXTEM clotting time; IN-CT, INTEM clotting time; CFT, clot formation time; alpha, α angle; A10, amplitude at 10/20 minutes; MCF, maximum clot firmness. *P <0.05.
Figure 2Receiver operating characteristic curve for amplitude at 10 minutes (A10) using intrinsic rotational thromboelastometry (INTEM) activator.
Rate of thromboembolic events in patients with hypercoagulability
|
|
|
|
|---|---|---|
|
| ||
| Hypercoagulable | 11.5 (3) | |
| Normal | 2.4 (7) | |
| Odds ratio | 5.22 | 0.01 |
|
| ||
| Hypercoagulable | 8.6 (5) | |
| Normal | 2.0 (5) | |
| Odds ratio | 4.72 | 0.009 |
|
| ||
| Hypercoagulable | 9.5 (4) | |
| Normal | 2.2 (6) | |
| Odds ratio | 4.65 | 0.01 |
INTEM, intrinsic rotational thromboelastometry; EXTEM, extrinsic rotational thromboelastometry; FIBTEM, fibrinogen rotational thromboelastometry.