Literature DB >> 25291953

Omalizumab (anti-IgE) therapy increases blood glucose levels in severe persistent allergic asthma patients with diabetes mellitus: 18 month follow-up.

Arzu Didem Yalcin, Reginald M Gorczynski, Aykut Cilli, Ludwig Strauss.   

Abstract

BACKGROUND: Therapeutic anti-IgE antibodies (Xolair, omalizumab) able to reduce free IgE levels and to block the binding of IgE to Fcepsilon RI without cross-linking IgE and triggering degranulation of IgE-sensitised cells have been developed.
METHODS: We had two male patients of severe persistent allergic asthma with type-2 diabetes mellitus at the ages of 57 and 52 and who had suffered a side-effect of increased blood glucose level that caused a need for an extra insulin injection to control the hyperglycemia. Their asthma was not under control, frequent emergency department admissions lead us to use omalizumab treatment. Assessment of clinical changes and adverse effects were evaluated at each bimonthly patient visit including vital signs, full physical examination, details of any allergy incidents, total and specific IgE levels, serum ECP (eosinophilic cationic peptid) levels, pulmonary function test, exhaled nitric oxide concentrations, and asthma control test.
RESULTS: Both patients were on week 42 - 45 of omalizumab treatment with a the dosage of 375 and 300 mg when they had the adverse reaction we reported here; they also had no other complaints. Blood levels of ECP and high sensitive CRP (hs-CRP) were decreased after starting the treatment of anti-IgE.
CONCLUSIONS: To our knowledge, this is the first time an association between omalizumab use and hyperglycemia has been documented. Every vial of Xolair (150 mg) contains 145.5 mg sucrose and it might increase the blood levels of glucose in diabetics. As a conclusion the prescribing information might have been revised based on post marketing surveillance data and reported such cases indicating that different side effects may occur beyond 2 hours of the injection.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25291953     DOI: 10.7754/clin.lab.2013.130302

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  6 in total

1.  AIR POLLUTION INFLUENCES ON EXHALED NITRIC OXIDE AMONG PEOPLE WITH TYPE II DIABETES.

Authors:  Cheng Peng; Heike Luttmann-Gibson; Antonella Zanobetti; Allison Cohen; Celine De Souza; Brent A Coull; Edward S Horton; Joel Schwartz; Petros Koutrakis; Diane R Gold
Journal:  Air Qual Atmos Health       Date:  2015-03-26       Impact factor: 3.763

Review 2.  An overview of the effects of anti-IgE therapies.

Authors:  Arzu Didem Yalcin
Journal:  Med Sci Monit       Date:  2014-09-22

3.  Choosing wisely: practical considerations on treatment efficacy and safety of asthma in the elderly.

Authors:  Nicola Scichilone; Maria T Ventura; Matteo Bonini; Fulvio Braido; Caterina Bucca; Marco Caminati; Stefano Del Giacco; Enrico Heffler; Carlo Lombardi; Andrea Matucci; Manlio Milanese; Roberto Paganelli; Giovanni Passalacqua; Vincenzo Patella; Erminia Ridolo; Giovanni Rolla; Oliviero Rossi; Domenico Schiavino; Gianenrico Senna; Gundi Steinhilber; Alessandra Vultaggio; Giorgio Canonica
Journal:  Clin Mol Allergy       Date:  2015-06-22

4.  Omalizumab usage in chronic urticaria and atopic dermatitis: data from South-East province of Turkey.

Authors:  Hülya Nazik; Mehmet Kamil Mülayim; Perihan Öztürk
Journal:  Postepy Dermatol Alergol       Date:  2019-12-30       Impact factor: 1.837

Review 5.  Association between Asthma and Type 2 Diabetes Mellitus: Mechanisms and Impact on Asthma Control-A Literature Review.

Authors:  Raimeyre Marques Torres; Marcela Dos Santos Souza; Ana Carla Carvalho Coelho; Luane Marques de Mello; Carolina Souza-Machado
Journal:  Can Respir J       Date:  2021-01-13       Impact factor: 2.409

6.  Case Report: Safety and Efficacy of Omalizumab in a 13-Year-Old Patient With Chronic Spontaneous Urticaria and Type 1 Diabetes.

Authors:  Paolo Del Barba; Federica Del Tedesco; Giulio Frontino; Maria Pia Guarneri; Riccardo Bonfanti; Graziano Barera
Journal:  Front Immunol       Date:  2022-04-12       Impact factor: 8.786

  6 in total