Literature DB >> 25285506

Lateral-flow assay for rapid quantitative detection of clorprenaline residue in swine urine.

Tao Peng1, Fu S Zhang2, Wan C Yang3, Dong X Li2, Yuan Chen3, Yong H Xiong1, Hua Wei1, Wei H Lai4.   

Abstract

Clorprenaline (CLP), a β2-adrenergic agonist, was first found in veterinary drugs for cold treatment in China in 2013. It is a potential new lean meat-boosting feed additive because it can promote animal muscular mass growth and decrease fat accumulation. A competitive colloidal gold-based lateral flow immunoassay system with a portable strip reader was successfully developed for rapid quantitative detection of CLP residue in swine urine. The detection system was optimized so that the detection can be completed within 9 min with a limit of detection of 0.15 μg · liter(-1). The assay exhibited good linear range from 3.0 to 20.0 μg · liter(-1), with reliable correlation of 0.9970 and with no obvious cross-reaction with five other β2-agonist compounds. Twenty spiked swine urine samples were tested by lateral flow immunoassay and liquid chromatography-tandem mass spectrometry to confirm the accuracy of the system. Results show good correlation between the two methods. This method is rapid, sensitive, specific, and convenient. It can be applied in the field for on-site detection of CLP in urine samples.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25285506     DOI: 10.4315/0362-028X.JFP-14-103

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  5 in total

1.  Immunochromatographic fluorometric determination of clenbuterol with enhanced sensitivity.

Authors:  Yuyang Zeng; Demei Liang; Pimiao Zheng; Tao Peng; Shujuan Sun; Ghulam Mujtaba Mari; Haiyang Jiang
Journal:  Mikrochim Acta       Date:  2019-03-08       Impact factor: 5.833

2.  Orientational binding modes of reporters in a viral-nanoparticle lateral flow assay.

Authors:  Jinsu Kim; Ryan Poling-Skutvik; João R C Trabuco; Katerina Kourentzi; Richard C Willson; Jacinta C Conrad
Journal:  Analyst       Date:  2016-12-19       Impact factor: 4.616

3.  Strategy for Accurate Detection of Escherichia Coli O157:H7 in Ground Pork Using a Lateral Flow Immunoassay.

Authors:  Song Cheng; Ming-Hui Chen; Gang-Gang Zhang; Zhi-Biao Yu; Dao-Feng Liu; Yong-Hua Xiong; Hua Wei; Wei-Hua Lai
Journal:  Sensors (Basel)       Date:  2017-04-02       Impact factor: 3.576

4.  Point-of-care test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2.

Authors:  Tao Peng; Zhiwei Sui; Zhenghui Huang; Jie Xie; Kai Wen; Yongzhuo Zhang; Wenfeng Huang; Wei Mi; Ke Peng; Xinhua Dai; Xiang Fang
Journal:  Sens Actuators B Chem       Date:  2021-01-04       Impact factor: 7.460

Review 5.  Paper-Based Fluidic Sensing Platforms for β-Adrenergic Agonist Residue Point-of-Care Testing.

Authors:  Hongzhi Luo; Shan Liu; Lina Shi; Zhu Li; Qianwen Bai; Xiaoxin Du; Lijun Wang; He Zha; Chenzhong Li
Journal:  Biosensors (Basel)       Date:  2022-07-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.