Literature DB >> 25284763

Superior versus temporal approach in descemet membrane endothelial keratoplasty.

Anna-Karina B Maier1, Enken Gundlach2, Johannes Gonnermann2, Matthias K J Klamann2, Antonia M Joussen2, Eckart Bertelmann2, Necip Torun2.   

Abstract

PURPOSE: To compare superior vs temporal approach in patients who underwent Descemet membrane endothelial keratoplasty (DMEK).
DESIGN: Monocentric, prospective nonmasked study.
METHODS: A prospective analysis of 53 DMEKs between January and September 2013 was performed at the Charité-Universitätsmedizin Berlin. Only DMEK cases with an incision size of 2.3 mm and with at least 1 month of follow-up were included. The surgically induced astigmatism (SIA), changes in corneal aberrations and in spherical equivalent, visual acuity, endothelial cell density, and complications were evaluated.
RESULTS: Visual acuity improved significantly (0.70 ± 0.39 logMAR vs 0.32 ± 0.31 logMAR after 1 month (n = 48), 0.19 ± 0.15 logMAR after 3 months (n = 46), and 0.16 ± 0.17 logMAR after 6 months (n = 47) (P < .001)) regardless of the approach. SIA was significantly lower after temporal than after superior approach (1.42 ± 0.91 diopters [D] [n = 13] vs 0.81 ± 0.68 D [n = 13], P = .038). Change in total root mean square of all aberrations (RMS) (P = .046) at 6 mm pupil diameter, and change in total RMS (P = .019), third-order aberrations (P = .007), and fourth-order aberrations (P = .041) at 4 mm pupil diameter, demonstrated significantly lower results after temporal compared to superior approach. A higher rate of eyes after temporal approach underwent at least 1 rebubbling (39.1% vs 26.7%, P = .252). The endothelial cell density (P = .053) and the change in spherical equivalent (P = .145) did not differ significantly.
CONCLUSIONS: The temporal approach induces significantly less SIA and corneal aberration. There are no significant differences between superior and temporal approach according to the change in spherical equivalent, visual acuity, and endothelial cell density. The need for rebubbling is higher using the temporal approach.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25284763     DOI: 10.1016/j.ajo.2014.09.042

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  [Refractive changes in triple Descemet membrane endothelial keratoplasty].

Authors:  C Girbardt; N Oertel; J Adamek-Dyk; P Wiedemann; A Nestler
Journal:  Ophthalmologe       Date:  2016-03       Impact factor: 1.059

Review 2.  [Triple Descemet membrane endothelial keratoplasty. Indications, variations and results].

Authors:  C Girbardt; P Wiedemann; A Nestler
Journal:  Ophthalmologe       Date:  2016-03       Impact factor: 1.059

Review 3.  Component corneal surgery: An update.

Authors:  Prafulla K Maharana; Pranita Sahay; Deepali Singhal; Itika Garg; Jeewan S Titiyal; Namrata Sharma
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.