Macro and micro full field x-ray fluorescence with an X-ray pinhole camera presenting high energy and high spatial resolution.

Francesco Paolo Romano1, Claudia Caliri, Luigi Cosentino, Santo Gammino, Lorenzo Giuntini, David Mascali, Lorenzo Neri, Lighea Pappalardo, Francesca Rizzo, Francesco Taccetti.   

Abstract

This work describes a tabletop (50 cm × 25 cm × 25 cm) full field X-ray pinhole camera (FF-XPC) presenting high energy- and high spatial-resolution. The FF-XPC consists of a conventional charge-coupled device (CCD) detector coupled, in a coaxial geometry, to a pinhole collimator of small diameter. The X-ray fluorescence (XRF) is induced on the samples with an external low-power X-ray tube. The use of the CCD as an energy dispersive X-ray detector was obtained by adopting a multi-image acquisition in single photon counting and by developing a processing algorithm to be applied in real-time to each of the acquired image-frames. This approach allowed the measurement of X-ray spectra with an energy resolution down to 133 eV at the reference value of 5.9 keV. The detection of the X-ray fluorescence through the pinhole-collimator allowed the two-dimensional elemental mapping of the irradiated samples. Two magnifications (M), determined by the relative sample-pinhole-CCD distances, are used in the present setup. A low value of M (equal to 0.35×) allows the macro-FF-XRF of large area samples (up to 4 × 4 cm(2)) with a spatial resolution down to 140 μm; a large magnification (M equal to 6×) is used for the micro-FF-XRF of small area samples (2.5 × 2.5 mm(2)) with a spatial resolution down to 30 μm.

Year:  2014        PMID: 25284509     DOI: 10.1021/ac503263h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Seeing elements by visible-light digital camera.

Authors:  Wenyang Zhao; Kenji Sakurai
Journal:  Sci Rep       Date:  2017-03-31       Impact factor: 4.379

2.  Investigation of Copper-Less Gas Electron Multiplier Detectors Responses to Soft X-rays.

Authors:  Bartosz Mindur; Tomasz Fiutowski; Stefan Koperny; Piotr Wiącek; Władysław Dąbrowski
Journal:  Sensors (Basel)       Date:  2020-05-14       Impact factor: 3.576

3.  Egyptian metallic inks on textiles from the 15th century BCE unravelled by non-invasive techniques and chemometric analysis.

Authors:  G Festa; T Christiansen; V Turina; M Borla; J Kelleher; L Arcidiacono; L Cartechini; R C Ponterio; C Scatigno; R Senesi; C Andreani
Journal:  Sci Rep       Date:  2019-05-13       Impact factor: 4.379

4.  Application of Factorisation Methods to Analysis of Elemental Distribution Maps Acquired with a Full-Field XRF Imaging Spectrometer.

Authors:  Bartłomiej Łach; Tomasz Fiutowski; Stefan Koperny; Paulina Krupska-Wolas; Marek Lankosz; Agata Mendys-Frodyma; Bartosz Mindur; Krzysztof Świentek; Piotr Wiącek; Paweł M Wróbel; Władysław Dąbrowski
Journal:  Sensors (Basel)       Date:  2021-11-29       Impact factor: 3.576

5.  Recent advances in analysis of trace elements in environmental samples by X-ray based techniques (IUPAC Technical Report).

Authors:  Roberto Terzano; Melissa A Denecke; Gerald Falkenberg; Bradley Miller; David Paterson; Koen Janssens
Journal:  Pure Appl Chem       Date:  2019       Impact factor: 2.453

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.