Literature DB >> 25284220

Continuous flow left ventricular pump support and its effect on regional left ventricular wall stress: finite element analysis study.

Choon-Sik Jhun1, Kay Sun, Joshua P Cysyk.   

Abstract

Left ventricular assist device (LVAD) support unloads left ventricular (LV) pressure and volume and decreases wall stress. This study investigated the effect of systematic LVAD unloading on the 3-dimensional myocardial wall stress by employing finite element models containing layered fiber structure, active contractility, and passive stiffness. The HeartMate II(®) (Thoratec, Inc., Pleasanton, CA) was used for LV unloading. The model geometries and hemodynamic conditions for baseline (BL) and LVAD support (LVsupport) were acquired from the Penn State mock circulatory cardiac simulator. Myocardial wall stress of BL was compared with that of LVsupport at 8,000, 9,000, 10,000 RPM, providing mean pump flow (Q(mean)) of 2.6, 3.2, and 3.7 l/min, respectively. LVAD support was more effective at unloading during diastole as compared to systole. Approximately 40, 50, and 60% of end-diastolic wall stress reduction were achieved at Q(mean) of 2.6, 3.2, and 3.7 l/min, respectively, as compared to only a 10% reduction of end-systolic wall stress at Q(mean) of 3.7 l/min. In addition, there was a stress concentration during systole at the apex due to the cannulation and reduced boundary motion. This modeling study can be used to further understand optimal unloading, pump control, patient management, and cannula design.

Entities:  

Mesh:

Year:  2014        PMID: 25284220     DOI: 10.1007/s11517-014-1205-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  39 in total

1.  Reshaping the remodelled left ventricle: a new concept.

Authors:  X M Mueller; H T Tevaearai; O Tucker; Y Boone; L K von Segesser
Journal:  Eur J Cardiothorac Surg       Date:  2001-10       Impact factor: 4.191

2.  Reversal of metallothionein expression is different throughout the human myocardium after prolonged left-ventricular mechanical support.

Authors:  H A Baba; F Grabellus; C August; G Plenz; A Takeda; T D Tjan; C Schmid; M C Deng
Journal:  J Heart Lung Transplant       Date:  2000-07       Impact factor: 10.247

3.  Reverse remodeling of the myocardial extracellular matrix after prolonged left ventricular assist device support follows a biphasic pattern.

Authors:  Annette H Bruggink; Matthijs F M van Oosterhout; Nicolaas de Jonge; Bas Ivangh; Joyce van Kuik; Ron H A M Voorbij; Jack P M Cleutjens; Frits H J Gmelig-Meyling; Roel A de Weger
Journal:  J Heart Lung Transplant       Date:  2006-08-02       Impact factor: 10.247

4.  Regression of cellular hypertrophy after left ventricular assist device support.

Authors:  A Zafeiridis; V Jeevanandam; S R Houser; K B Margulies
Journal:  Circulation       Date:  1998-08-18       Impact factor: 29.690

5.  Beneficial effects of the CorCap cardiac support device: five-year results from the Acorn Trial.

Authors:  Douglas L Mann; Spencer H Kubo; Hani N Sabbah; Randall C Starling; Mariell Jessup; Jae K Oh; Michael A Acker
Journal:  J Thorac Cardiovasc Surg       Date:  2011-07-16       Impact factor: 5.209

Review 6.  Reverse remodeling following insertion of left ventricular assist devices (LVAD): a review of the morphological and molecular changes.

Authors:  Jeremias Wohlschlaeger; Klaus J Schmitz; Christof Schmid; Kurt W Schmid; Petra Keul; Atsushi Takeda; Serge Weis; Bodo Levkau; Hideo A Baba
Journal:  Cardiovasc Res       Date:  2005-07-18       Impact factor: 10.787

7.  Management of aortic valve insufficiency in patients supported by long-term continuous flow left ventricular assist devices.

Authors:  Jeffrey A Morgan; Robert J Brewer; Hassan W Nemeh; Scott E Henry; Narula Neha; Celeste T Williams; David E Lanfear; Cristina Tita; Gaetano Paone
Journal:  Ann Thorac Surg       Date:  2012-11       Impact factor: 4.330

8.  Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model.

Authors:  R W Smalling; D B Cassidy; R Barrett; B Lachterman; P Felli; J Amirian
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

9.  Cardiac hypertrophy: useful adaptation or pathologic process?

Authors:  W Grossman
Journal:  Am J Med       Date:  1980-10       Impact factor: 4.965

10.  Alterations of gene expression in failing myocardium following left ventricular assist device support.

Authors:  YingJie Chen; Soon Park; Yunfang Li; Emil Missov; Mingxiao Hou; Xinqiang Han; Jennifer L Hall; Leslie W Miller; Robert J Bache
Journal:  Physiol Genomics       Date:  2003-08-15       Impact factor: 3.107

View more
  5 in total

Review 1.  Biomechanics of Cardiac Function.

Authors:  Andrew P Voorhees; Hai-Chao Han
Journal:  Compr Physiol       Date:  2015-09-20       Impact factor: 9.090

2.  Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico.

Authors:  Kevin L Sack; Brian Baillargeon; Gabriel Acevedo-Bolton; Martin Genet; Nuno Rebelo; Ellen Kuhl; Liviu Klein; Georg M Weiselthaler; Daniel Burkhoff; Thomas Franz; Julius M Guccione
Journal:  Int J Artif Organs       Date:  2016-09-14       Impact factor: 1.595

3.  Computational analysis of the effect of mitral and aortic regurgitation on the function of ventricular assist devices using 3D cardiac electromechanical model.

Authors:  Yoo Seok Kim; Ana R Yuniarti; Kwang-Soup Song; Natalia A Trayanova; Eun Bo Shim; Ki Moo Lim
Journal:  Med Biol Eng Comput       Date:  2017-10-28       Impact factor: 2.602

4.  Computational analysis of the hemodynamic characteristics under interaction influence of β-blocker and LVAD.

Authors:  Kaiyun Gu; Zhe Zhang; Yu Chang; Bin Gao; Feng Wan
Journal:  Biomed Eng Online       Date:  2018-12-03       Impact factor: 2.819

5.  In vivo estimation of passive biomechanical properties of human myocardium.

Authors:  Arnab Palit; Sunil K Bhudia; Theodoros N Arvanitis; Glen A Turley; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2018-02-26       Impact factor: 2.602

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.