Literature DB >> 25283449

Droplet-based immunoassay on a 'sticky' nanofibrous surface for multiplexed and dual detection of bacteria using smartphones.

Ariana M Nicolini1, Christopher F Fronczek1, Jeong-Yeol Yoon2.   

Abstract

We have developed a rapid, sensitive, and specific droplet-based immunoassay for the detection of Escherichia coli and Salmonella within a single-pipetted sample. Polycaprolactone (PCL) electrospun fibers on indium-tin-oxide (ITO) glass provide a sufficient surface to render a non-slip droplet condition, and while the PCL fibers lend a local hydrophilicity (contact angle θ=74°) for sufficient sub-micron particle adhesion, air pockets within the fibers lend an apparent hydrophobicity. Overall, the contact angle of water on this electrospun surface is 119°, and the air pockets cause the droplet to be completely immobile and resistant to movement, protecting it from external vibration. By using both anti-E. coli conjugated, 510 nm diameter green fluorescent particles (480 nm excitation and 520 nm emission) and anti-Salmonella conjugated, 400 nm diameter red fluorescent particles (640 nm excitation and 690 nm emission), we can detect multiple targets in a single droplet. Using appropriate light sources guided by fiber optics, we determined a detection limit of 10(2) CFU mL(-1). Immunoagglutination can be observed under a fluorescence microscope. Fluorescence detection (at the emission wavelength) of immunoagglutination was maximum at 90° from the incident light, while light scattering (at the excitation wavelength) was still present and behaved similarly, indicating the ability of double detection, greatly improving credibility and reproducibility of the assay. A power function (light intensity) simulation of elastic Mie scatter confirmed that both fluorescence and light scattering were present. Due to the size of the fluorescent particles relative to their incident excitation wavelengths, Mie scatter conditions were observed, and fluorescence signals show a similar trend to light scattering signals. Smartphone detection was included for true portable detection, in which the high contact angle pinning of the droplet makes this format re-usable and re-configurable.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Droplet; Electrospinning; Fluorescence; Immunoagglutination; Light scatter; Smartphone

Mesh:

Substances:

Year:  2014        PMID: 25283449     DOI: 10.1016/j.bios.2014.09.040

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  12 in total

Review 1.  Imaging, Identification and Inhibition of Microorganisms Using AIEgens.

Authors:  Harini A Perera; Mingdi Yan
Journal:  Top Curr Chem (Cham)       Date:  2021-04-09

2.  Angular photodiode array-based device to detect bacterial pathogens in a wound model.

Authors:  Robin E Sweeney; Jeong-Yeol Yoon
Journal:  IEEE Sens J       Date:  2017-09-14       Impact factor: 3.301

Review 3.  Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing.

Authors:  Bhaskar Das; Javier Lou Franco; Natasha Logan; Paramasivan Balasubramanian; Moon Il Kim; Cuong Cao
Journal:  Nanomicro Lett       Date:  2021-09-13

4.  Optical Biosensing of Bacteria and Bacterial Communities.

Authors:  Jiayun Hu; Paul W Bohn
Journal:  J Anal Test       Date:  2017-02-06

Review 5.  Recent Advances in Electrospun Nanofiber Interfaces for Biosensing Devices.

Authors:  Eleni Sapountzi; Mohamed Braiek; Jean-François Chateaux; Nicole Jaffrezic-Renault; Florence Lagarde
Journal:  Sensors (Basel)       Date:  2017-08-16       Impact factor: 3.576

6.  Paper strip-embedded graphene quantum dots: a screening device with a smartphone readout.

Authors:  Ruslan Álvarez-Diduk; Jahir Orozco; Arben Merkoçi
Journal:  Sci Rep       Date:  2017-04-20       Impact factor: 4.379

7.  Plasmonics Enhanced Smartphone Fluorescence Microscopy.

Authors:  Qingshan Wei; Guillermo Acuna; Seungkyeum Kim; Carolin Vietz; Derek Tseng; Jongjae Chae; Daniel Shir; Wei Luo; Philip Tinnefeld; Aydogan Ozcan
Journal:  Sci Rep       Date:  2017-05-18       Impact factor: 4.379

Review 8.  Advances in Optical Detection of Human-Associated Pathogenic Bacteria.

Authors:  Andrea Locke; Sean Fitzgerald; Anita Mahadevan-Jansen
Journal:  Molecules       Date:  2020-11-11       Impact factor: 4.411

Review 9.  Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health.

Authors:  Reuven Rasooly; Hugh Alan Bruck; Joshua Balsam; Ben Prickril; Miguel Ossandon; Avraham Rasooly
Journal:  Diagnostics (Basel)       Date:  2016-05-17

Review 10.  Smartphone-Based Biosensor Devices for Healthcare: Technologies, Trends, and Adoption by End-Users.

Authors:  Rossana E Madrid; Fernando Ashur Ramallo; Daniela E Barraza; Roberto E Chaile
Journal:  Bioengineering (Basel)       Date:  2022-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.