Literature DB >> 25281985

Breast cancer detection using interferometric MUSIC: experimental and numerical assessment.

Giuseppe Ruvio1, Raffaele Solimene2, Antonio Cuccaro2, Domenico Gaetano3, Jacinta E Browne4, Max J Ammann3.   

Abstract

PURPOSE: In microwave breast cancer detection, it is often beneficial to arrange sensors in close proximity to the breast. The resultant coupling generally changes the antenna response. As an a priori characterization of the radio frequency system becomes difficult, this can lead to severe degradation of the detection efficacy. The purpose of this paper is to demonstrate the advantages of adopting an interferometric multiple signal classification (I-MUSIC) approach due to its limited dependence from a priori information on the antenna. The performance of I-MUSIC detection was measured in terms of signal-to-clutter ratio (SCR), signal-to-mean ratio (SMR), and spatial displacement (SD) and compared to other common linear noncoherent imaging methods, such as migration and the standard wideband MUSIC (WB-MUSIC) which also works when the antenna is not accounted for.
METHODS: The data were acquired by scanning a synthetic oil-in-gelatin phantom that mimics the dielectric properties of breast tissues across the spectrum 1-3 GHz using a proprietary breast microwave multi-monostatic radar system. The phantom is a multilayer structure that includes skin, adipose, fibroconnective, fibroglandular, and tumor tissue with an adipose component accounting for 60% of the whole structure. The detected tumor has a diameter of 5 mm and is inserted inside a fibroglandular region with a permittivity contrast εr-tumor/εr-fibroglandular < 1.5 over the operating band. Three datasets were recorded corresponding to three antennas with different coupling mechanisms. This was done to assess the independence of the I-MUSIC method from antenna characterizations. The datasets were processed by using I-MUSIC, noncoherent migration, and wideband MUSIC under equivalent conditions (i.e., operative bandwidth, frequency samples, and scanning positions). SCR, SMR, and SD figures were measured from all reconstructed images. In order to benchmark experimental results, numerical simulations of equivalent scenarios were carried out by using CST Microwave Studio. The three numerical datasets were then processed following the same procedure that was designed for the experimental case.
RESULTS: Detection results are presented for both experimental and numerical phantoms, and higher performance of the I-MUSIC method in comparison with the WB-MUSIC and noncoherent migration is achieved. This finding is confirmed for the three different antennas in this study. Although a delocalization effect occurs, experimental datasets show that the signal-to-clutter ratio and the signal-to-mean performance with the I-MUSIC are at least 5 and 2.3 times better than the other methods, respectively. The numerical datasets calculated on an equivalent phantom for cross-testing confirm the improved performance of the I-MUSIC in terms of SCR and SMR. In numerical simulations, the delocalization effect is dramatically reduced up to an SD value of 1.61 achieved with the I-MUSIC in combination with the antipodal Vivaldi antenna. This shows that mechanical uncertainties are the main reason for the delocalization effect in the measurements.
CONCLUSIONS: Experimental results show that the I-MUSIC generates images with signal-to-clutter levels higher than 5.46 dB across all working conditions and it reaches 7.84 dB in combination with the antipodal Vivaldi antenna. Numerical simulations confirm this trend and due to ideal mechanical conditions return a signal-to-clutter level higher than 7.61 dB. The I-MUSIC largely outperforms the methods under comparison and is able to detect a 5-mm tumor with a permittivity contrast of 1.5.

Entities:  

Mesh:

Year:  2014        PMID: 25281985     DOI: 10.1118/1.4892067

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Microwave bone imaging: a preliminary scanning system for proof-of-concept.

Authors:  Giuseppe Ruvio; Antonio Cuccaro; Raffaele Solimene; Adriana Brancaccio; Bruno Basile; Max J Ammann
Journal:  Healthc Technol Lett       Date:  2016-06-30

2.  Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging.

Authors:  Giuseppe Ruvio; Raffaele Solimene; Antonio Cuccaro; Gaia Fiaschetti; Andrew J Fagan; Sean Cournane; Jennie Cooke; Max J Ammann; Jorge Tobon; Jacinta E Browne
Journal:  Sensors (Basel)       Date:  2020-04-23       Impact factor: 3.576

3.  Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment.

Authors:  Matteo Savazzi; Soroush Abedi; Niko Ištuk; Nadine Joachimowicz; Hélène Roussel; Emily Porter; Martin O'Halloran; Jorge R Costa; Carlos A Fernandes; João M Felício; Raquel C Conceição
Journal:  Sensors (Basel)       Date:  2020-09-02       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.