Literature DB >> 25281948

Design of an Yb-169 source optimized for gold nanoparticle-aided radiation therapy.

Francisco J Reynoso1, Nivedh Manohar1, Sunil Krishnan2, Sang Hyun Cho3.   

Abstract

PURPOSE: To find an optimum design of a new high-dose rate ytterbium (Yb)-169 brachytherapy source that would maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT), while meeting practical constraints for manufacturing a clinically relevant brachytherapy source.
METHODS: Four different Yb-169 source designs were considered in this investigation. The first three source models had a single encapsulation made of one of the following materials: aluminum, titanium, and stainless steel. The last source model adopted a dual encapsulation design with an inner aluminum capsule surrounding the Yb-core and an outer titanium capsule. Monte Carlo (MC) simulations using the Monte Carlo N-Particle code version 5 (MCNP5) were conducted initially to investigate the spectral changes caused by these four source designs and the associated variations in macroscopic dose enhancement across the tumor loaded with gold nanoparticles (GNPs) at 0.7% by weight. Subsequent MC simulations were performed using the EGSnrc and norec codes to determine the secondary electron spectra and microscopic dose enhancement as a result of irradiating the GNP-loaded tumor with the mcnp-calculated source spectra.
RESULTS: Effects of the source filter design were apparent in the current MC results. The intensity-weighted average energy of the Yb-169 source varied from 108.9 to 122.9 keV, as the source encapsulation material changed from aluminum to stainless steel. Accordingly, the macroscopic dose enhancement calculated at 1 cm away from the source changed from 51.0% to 45.3%. The sources encapsulated by titanium and aluminum/titanium combination showed similar levels of dose enhancement, 49.3% at 1 cm, and average energies of 113.0 and 112.3 keV, respectively. While the secondary electron spectra due to the investigated source designs appeared to look similar in general, some differences were noted especially in the low energy region (<50 keV) of the spectra suggesting the dependence of the photoelectron yield on the atomic number of source filter material, consistent with the macroscopic dose enhancement results. A similar trend was also shown in the so-called microscopic dose enhancement factor, for example, resulting in the maximum values of 138 and 119 for the titanium- and the stainless steel-encapsulated Yb-169 sources, respectively.
CONCLUSIONS: The current results consistently show that the dose enhancement achievable from the Yb-169 source is closely related with the atomic number (Z) of source encapsulation material. While the observed range of improvement in the dose enhancement may be considered moderate after factoring all uncertainties in the MC results, the current study provides a reasonable support for the encapsulation of the Yb-core with lower-Z materials than stainless steel, for GNRT applications. Overall, the titanium capsule design can be favored over the aluminum or dual aluminum/titanium capsule designs, due to its superior structural integrity and improved safety during manufacturing and clinical use.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25281948     DOI: 10.1118/1.4895991

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Development of bimetallic (Zn@Au) nanoparticles as potential PET-imageable radiosensitizers.

Authors:  Jongmin Cho; Min Wang; Carlos Gonzalez-Lepera; Osama Mawlawi; Sang Hyun Cho
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

2.  Radiosensitization of Prostate Cancers In Vitro and In Vivo to Erbium-filtered Orthovoltage X-rays Using Actively Targeted Gold Nanoparticles.

Authors:  Allison M Khoo; Sang Hyun Cho; Francisco J Reynoso; Maureen Aliru; Kathryn Aziz; Monica Bodd; Xi Yang; Md F Ahmed; Selcuk Yasar; Nivedh Manohar; Jongmin Cho; Ramesh Tailor; Howard D Thames; Sunil Krishnan
Journal:  Sci Rep       Date:  2017-12-22       Impact factor: 4.379

3.  Technical Note: Monte Carlo calculations of the AAPM TG-43 brachytherapy dosimetry parameters for a new titanium-encapsulated Yb-169 source.

Authors:  Francisco J Reynoso; John J Munro Iii; Sang Hyun Cho
Journal:  J Appl Clin Med Phys       Date:  2017-06-06       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.