Improving the excess kurtosis (g2) method for localizing epileptic sources in magnetoencephalographic recordings.

Yuval Harpaz1, Stephen E Robinson2, Mordekhay Medvedovsky3, Abraham Goldstein4.   

Abstract

OBJECTIVE: To suggest ways to apply the excess kurtosis estimator g2, in the detection of epileptic activity with magnetoencephalography, while avoiding its bias towards detecting high-amplitude, infrequent events.
METHODS: Synthetic aperture magnetometry (SAM), combined with g2, was applied using window lengths ranging from 0.125 s to 32 s and with sum and maximum metrics on simulated data and recordings of two focal epilepsy patients.
RESULTS: Comparing sources with different spike rates (two per second and one per 2s), the sum metric was most efficient when using a window of 0.25s. Simulations showed that the sum metric is insensitive to spike frequency when the window includes more than one spike. SAM(g2) images from long segments with maximum metric resulted in misleading images, showing the strongest activity away from the lesions.
CONCLUSIONS: Using a sliding window and the sum metric is beneficial when imaging interictal spikes and status epilepticus. Windows should be short enough not to include more than one interictal event. For continuous events such as electrographic seizures windows should contain baseline data and the epileptic event. SIGNIFICANCE: The sliding window and metric should be set according to the suggested guidelines when using SAM(g2) for presurgical evaluation.
Copyright © 2014 International Federation of Clinical Neurophysiology. All rights reserved.

Entities:  

Keywords:  Beamforming; Epilepsy; Kurtosis; Source localization; Spike

Mesh:

Year:  2014        PMID: 25281474     DOI: 10.1016/j.clinph.2014.09.002

Source DB:  PubMed          Journal:  Clin Neurophysiol        ISSN: 1388-2457            Impact factor:   3.708


  3 in total

1.  Localization of Interictal Epileptic Spikes With MEG: Optimization of an Automated Beamformer Screening Method (SAMepi) in a Diverse Epilepsy Population.

Authors:  Jonathan M Scott; Stephen E Robinson; Tom Holroyd; Richard Coppola; Susumu Sato; Sara K Inati
Journal:  J Clin Neurophysiol       Date:  2016-10       Impact factor: 2.177

2.  An evaluation of kurtosis beamforming in magnetoencephalography to localize the epileptogenic zone in drug resistant epilepsy patients.

Authors:  Michael B H Hall; Ida A Nissen; Elisabeth C W van Straaten; Paul L Furlong; Caroline Witton; Elaine Foley; Stefano Seri; Arjan Hillebrand
Journal:  Clin Neurophysiol       Date:  2018-03-09       Impact factor: 3.708

3.  Interictal magnetoencephalography in parietal lobe epilepsy - Comparison of equivalent current dipole and beamformer (SAMepi) analysis.

Authors:  Juha Wilenius; Leena Lauronen; Erika Kirveskari; Eija Gaily; Liisa Metsähonkala; Ritva Paetau
Journal:  Clin Neurophysiol Pract       Date:  2020-03-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.