Literature DB >> 25281140

Determination of urine ionic composition with potentiometric multisensor system.

Irina Yaroshenko1, Dmitry Kirsanov2, Lyudmila Kartsova3, Alla Sidorova4, Irina Borisova4, Andrey Legin5.   

Abstract

The ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biochemical analysis of urine; Chemometrics; Electronic tongue; Potentiometric multisensor system; Urine ionic composition

Mesh:

Substances:

Year:  2014        PMID: 25281140     DOI: 10.1016/j.talanta.2014.08.030

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  8 in total

1.  Nitrate and carbon matter removals from real effluents using Si/BDD electrode.

Authors:  Mouna Ghazouani; Hanene Akrout; Latifa Bousselmi
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-13       Impact factor: 4.223

Review 2.  Electronic Tongue-A Tool for All Tastes?

Authors:  Marta Podrażka; Ewa Bączyńska; Magdalena Kundys; Paulina S Jeleń; Emilia Witkowska Nery
Journal:  Biosensors (Basel)       Date:  2017-12-31

Review 3.  Multisensor Systems and Arrays for Medical Applications Employing Naturally-Occurring Compounds and Materials.

Authors:  Rasa Pauliukaite; Edita Voitechovič
Journal:  Sensors (Basel)       Date:  2020-06-23       Impact factor: 3.576

4.  Biological Assessment of Zn-Based Absorbable Metals for Ureteral Stent Applications.

Authors:  Devi Paramitha; Stéphane Chabaud; Stéphane Bolduc; Hendra Hermawan
Journal:  Materials (Basel)       Date:  2019-10-12       Impact factor: 3.623

Review 5.  Electronic Tongues for Inedible Media.

Authors:  Dmitry Kirsanov; Daniel S Correa; Gabriel Gaal; Antonio Riul; Maria L Braunger; Flavio M Shimizu; Osvaldo N Oliveira; Tao Liang; Hao Wan; Ping Wang; Ekaterina Oleneva; Andrey Legin
Journal:  Sensors (Basel)       Date:  2019-11-22       Impact factor: 3.576

6.  A Co-Nanoparticles Modified Electrode for On-Site and Rapid Phosphate Detection in Hydroponic Solutions.

Authors:  Feng Xu; Peng Wang; Shiyuan Bian; Yuliang Wei; Deyi Kong; Huanqin Wang
Journal:  Sensors (Basel)       Date:  2021-01-05       Impact factor: 3.576

Review 7.  Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection.

Authors:  Jiawei Zhai; Bin Luo; Aixue Li; Hongtu Dong; Xiaotong Jin; Xiaodong Wang
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

Review 8.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.