Randomized controlled pilot trial of the rigid and flexing laryngoscope versus the fiberoptic bronchoscope for intubation of potentially difficult airway.

B D Alvis1, A B King, D Hester, C G Hughes, M S Higgins.   

Abstract

BACKGROUND: The flexible fiberoptic bronchoscope (FOB) is viewed as the gold standard device for awake intubation in the difficult airway. The newer rigid flexible laryngoscope (RIFL) was developed for similar indications. In this study we compare these two devices for management of potentially difficult airways after induction of general anesthesia.
METHODS: Adult surgical patients requiring endotracheal intubation and having a predicted difficult airway based on airway examination, BMI≥35, and/or history of prior difficult intubation were randomized to undergo endotracheal intubation with either the RIFL or FOB. Induction was performed in usual manner, and intubation was performed by providers proficient with both airway devices after induction of general anesthesia. The primary outcomes measured were intubation success, time to intubation, number of attempts, and the need for airway assist maneuvers. The lowest observed oxygen saturation and airway trauma were also recorded.
RESULTS: A total of 41 patients were enrolled, with 20 randomized to each group and 1 withdrawal. Intubation was successful in all patients with both devices. The median time for successful intubation was significantly shorter in the RIFL group compared to the FOB group (49 vs. 64 seconds; P=0.048). Airway assist maneuvers were required in 2 (10%) intubations with the RIFL compared to 16 (80%) intubations with the FOB (P<0.001). There were no significant differences in lowest oxygen saturation or airway trauma.
CONCLUSION: The RIFL required significantly less time and fewer airway assist maneuvers for successful endotracheal intubation compared to FOB when used by experienced providers in patients with anticipated difficult airways.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25280140

Source DB:  PubMed          Journal:  Minerva Anestesiol        ISSN: 0375-9393            Impact factor:   3.051