Finite element analysis of stability and functional stress with implant-supported maxillary obturator prostheses.

Andréa Alves de Sousa1, Beatriz Silva Câmara Mattos2.   

Abstract

STATEMENT OF PROBLEM: Maxillary resections jeopardize the stability and functional stress generated by implanted-supported prostheses.
PURPOSE: The purpose of this study was to evaluate the stability and functional stress caused by implanted-supported obturator prostheses in simulated maxillary resections of an edentulous maxilla corresponding to Okay Classes Ib, II, and III, with no surgical reconstruction.
MATERIAL AND METHODS: Implants were positioned in the residual maxilla, and bar-clip retention systems were designed for each experimental model. The 3-dimensional models of the maxillary resection and corresponding implanted-supported obturator prosthesis, constructed from a computed tomography scan, were used to develop a finite element mesh. Loads were simultaneously applied to the occlusal (80 N) and anterior (35 N) platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained by means of quantitative analysis were expressed in MPa.
RESULTS: The implant-supported obturator prostheses tended to rotate toward the surgical resection, the region with no osseous support. Tensile and compressive stresses in the gingival mucosa and in the cortical bone increased as the osseous support and the numbers of implants and clips diminished.
CONCLUSIONS: All evaluated bar-clip retention systems displayed a tendency toward dislodgment of the obturator prosthesis, increasing as the osseous resection area amplified. The osseous tensile and compressive stresses resulting from the bar-clip retention system for Okay Classes Ib, II, and III maxillectomy may not be favorable to the survival rate of implants.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25277029     DOI: 10.1016/j.prosdent.2014.06.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

Review 1.  Finite element analysis: A boon to dentistry.

Authors:  Shilpa Trivedi
Journal:  J Oral Biol Craniofac Res       Date:  2014-12-04

2.  Biomechanical Stress in Obturator Prostheses: A Systematic Review of Finite Element Studies.

Authors:  Mohammed A Mousa; Johari Yap Abdullah; Nafij B Jamayet; Mohammad Khursheed Alam; Adam Husein
Journal:  Biomed Res Int       Date:  2021-08-16       Impact factor: 3.411

3.  Stress distribution on different bar materials in implant-retained palatal obturator.

Authors:  Regina Furbino Villefort; João Paulo Mendes Tribst; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Borges; Nívia Castro Binda; Carlos Eduardo de Almeida Ferreira; Marco Antonio Bottino; Sandra Lúcia Ventorim von Zeidler
Journal:  PLoS One       Date:  2020-10-30       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.