| Literature DB >> 25276417 |
Pavel Studeny1, Deli Krizova1, Zbynek Stranak1.
Abstract
Purpose. The aim of this work was to evaluate the results after combined surgery implantation of full rings and CXL in one session in a group of patients with keratoconus during a 12-month follow-up. Material and Methods. The study included 22 eyes of 20 keratoconic patients, mean age of 28.41 (from 18 to 50) years. A full ring was inserted and afterwards 0.1% riboflavin solution was injected into the corneal pocket through the incision tunnel. The cornea was irradiated with UV-A light for 30 minutes. Postoperative visits were scheduled for the first week and months 1, 3, 6, 12, and 24 after surgery. Minimal follow-up time was 12 months. Results. The mean UDVA improved by 6 lines from before the operation to 1 year after the operation, the mean CDVA improved by approximately 2.5 lines, and the mean K improved by 3.94 D. Statistically significant reductions of sphere (P < 0.001), cylinder (P = 0.004), and spherical (P < 0.001) equivalents were found 1 month after surgery. Conclusion. The combined surgery MyoRing implantation and CXL seems to be a safe method in the treatment of keratoconus. We noticed an improvement of the refractive error in all of our patients.Entities:
Year: 2014 PMID: 25276417 PMCID: PMC4172981 DOI: 10.1155/2014/568128
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Visual and refractive outcomes over time.
| Mean ± SD | ||||||
|---|---|---|---|---|---|---|
| Variable | Preoperative | Postoperative |
| |||
| 1 Months | 6 Months | 1 Year | 2 Years | |||
| UDVA (logMAR) | 0.89 ± 0.38 | 0.61 ± 0.34 | 0.42 ± 0.26 | 0.33 ± 0.23 | 0.29 ± 0.26 | =0.012 |
| CDVA (logMAR) | 0.44 ± 0.20 | 0.36 ± 0.22 | 0.22 ± 0.12 | 0.19 ± 0.09 | 0.16 ± 0.10 | <0.001 |
| Sphere (D) | −4.01 ± 3.21 | −1.54 ± 2.57 | −0.94 ± 2.07 | −1.25 ± 0.94 | −1.8 ± 0.58 | <0.001 |
| Cylinder (D) | −2.98 ± 2.67 | −1.15 ± 1.78 | −1.53 ± 2.10 | −1.37 ± 1.43 | −0.95 ± 1.54 | =0.025 |
| Mean K (D) | 51.05 ± 4.51 | 47.27 ± 5.27 | 46.8 ± 4.64 | 47.11 ± 4.57 | 47.34 ± 5.85 | <0.001 |
| Corneal astigmatism (D) | 4.62 ± 3.23 | 3.12 ± 1.92 | 1.66 ± 0.9 | 2.96 ± 1.65 | 2.35 ± 1.14 | =0.048 |
CDVA = corrected distance visual acuity; K = keratometry; UDVA = uncorrected distance visual acuity.
P value—change from preoperatively to 1 year postoperatively (paired Student t test).
Figure 1Mean UDVA over time. The error bars represent the SD in logMAR (UDVA: uncorrected distance visual acuity).
Figure 2Mean CDVA over time. The error bars represent the SD in logMAR (CDVA: corrected distance visual acuity).
Keratometry (D) and pachymetry (µm) over time.
| Mean ± SD | ||||||
|---|---|---|---|---|---|---|
| Variable | Preoperative | Postoperative |
| |||
| 1 Months | 6 Months | 1 Year | 2 Years | |||
|
| 48.80 ± 4.68 | 45.72 ± 5.37 | 45.17 ± 4.72 | 45.62 ± 4.55 | 46.16 ± 5.78 | <0.001 |
|
| 53.30 ± 4.95 | 48.82 ± 5.35 | 48.44 ± 4.74 | 48.59 ± 4.75 | 48.51 ± 5.98 | <0.001 |
|
| 51.05 ± 4.52 | 47.27 ± 5.28 | 46.72 ± 4.63 | 47.05 ± 4.57 | 47.3 ± 5.85 | <0.001 |
| Pachymetry (thinnest location) | 429.18 ± 29.47 | 432.09 ± 40.49 | 425.80 ± 41.50 | 423.29 ± 41.23 | 432.73 ± 33.60 | =0.210 |
D = diopters; µm = micrometres; K 1 = corneal dioptric power in the flattest meridian for the 3-mm central zone, K 2 = corneal dioptric power in the steepest meridian for the 3-mm central zone, K = mean corneal power in the 3-mm central zone.
P value—change from preoperatively to 1 year postoperatively (paired Student t test).
Figure 3Keratometric changes after MyoRing implantation and CXL. D: diopters; K 1: corneal dioptric power in the flattest meridian for the 3 mm central zone; K 2: corneal dioptric power in the steepest meridian for the 3 mm central zone; K : mean corneal power in the 3 mm central zone.
Figure 4Pachymetric changes after MyoRing implantation and CXL. μm: micrometer. The error bars represent the SD in μm.