Literature DB >> 25274091

Subpectoral biceps tenodesis: a new technique using an all-suture anchor fixation.

Wei-Ren Su1, Florence Y Ling, Chih-Kai Hong, Chih-Hsun Chang, Cheng-Li Lin, I-Ming Jou.   

Abstract

UNLABELLED: There are several options for LHB tenodesis; yet, there is no standard of care. This technical note describes an extramedullary all-suture anchor technique for LHB tenodesis that is similar to the extramedullary cortical button technique. The LHB tenodesis is performed by using the Y-Knot (1.3-mm; ConMed Linvatec, Largo, FL).The biceps tenotomy is completed arthroscopically, and a standard subpectoral approach is used for the tenodesis. A reamer is first used to drill through the anterior cortex of the humerus; subsequently, a 1.3-mm drill bit is used to drill through the posterior cortex. The Y-Knot anchor is passed through the bone tunnel and secured on the posterior cortical bone. A modified rolling hitch suture is placed 10 mm distal to the end of the LHB tendon by using one suture limb of the Y-Knot anchor. The other suture limb is pulled to shuttle the LHB tendon into the humerus, and the construct is fixed by tying down one limb to the other. This technical note describes an alternative method for subpectoral biceps tenodesis and uses a small drill hole, conserves bone, and minimizes trauma to the tendon. LEVEL OF EVIDENCE: V.

Entities:  

Mesh:

Year:  2014        PMID: 25274091     DOI: 10.1007/s00167-014-3348-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  18 in total

1.  Biomechanical evaluation of classic solid and novel all-soft suture anchors for glenoid labral repair.

Authors:  Augustus D Mazzocca; David Chowaniec; Mark P Cote; Joel Fierra; John Apostolakos; Michael Nowak; Robert A Arciero; Knut Beitzel
Journal:  Arthroscopy       Date:  2012-02-01       Impact factor: 4.772

2.  The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis.

Authors:  Augustus D Mazzocca; James Bicos; Stephen Santangelo; Anthony A Romeo; Robert A Arciero
Journal:  Arthroscopy       Date:  2005-11       Impact factor: 4.772

Review 3.  Subpectoral biceps tenodesis.

Authors:  Matthew T Provencher; Lance E LeClere; Anthony A Romeo
Journal:  Sports Med Arthrosc Rev       Date:  2008-09       Impact factor: 1.985

4.  Long head of the biceps tenodesis with cortical button technique.

Authors:  Nimrod Snir; Mathew Hamula; Theodore Wolfson; Catherine Laible; Orrin Sherman
Journal:  Arthrosc Tech       Date:  2013-03-25

5.  Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor.

Authors:  Tim Dwyer; Thomas L Willett; Andrew P Dold; Massimo Petrera; David Wasserstein; Danny B Whelan; John S Theodoropoulos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-08       Impact factor: 4.342

6.  Biomechanical comparison of arthroscopically performable techniques for suprapectoral biceps tenodesis.

Authors:  Thilo Patzer; Jan M Rundic; Evgenij Bobrowitsch; Gavin D Olender; Christof Hurschler; Markus D Schofer
Journal:  Arthroscopy       Date:  2011-06-24       Impact factor: 4.772

7.  Biomechanical evaluation of a unicortical button versus interference screw for subpectoral biceps tenodesis.

Authors:  Amarpal S Arora; Anshu Singh; Ryan C Koonce
Journal:  Arthroscopy       Date:  2013-02-06       Impact factor: 4.772

8.  Hamstring graft preparation using a modified rolling hitch technique.

Authors:  Chih-Kai Hong; Chih-Hsun Chang; Chen-Hao Chiang; I-Ming Jou; Wei-Ren Su
Journal:  Arthrosc Tech       Date:  2014-05-12

9.  A humerus fracture in a baseball pitcher after biceps tenodesis.

Authors:  Eric J Dein; Gazi Huri; John C Gordon; Edward G McFarland
Journal:  Am J Sports Med       Date:  2014-02-05       Impact factor: 6.202

10.  Arthroscopic biceps tenodesis: a new technique using bioabsorbable interference screw fixation.

Authors:  Pascal Boileau; Sumant G Krishnan; Jean-Sebastien Coste; Gilles Walch
Journal:  Arthroscopy       Date:  2002 Nov-Dec       Impact factor: 4.772

View more
  8 in total

1.  Arthroscopic Transtendinous Biceps Tenodesis With All-Suture Anchor.

Authors:  Chien-An Shih; Florence L Chiang; Chih-Kai Hong; Cheng-Wei Lin; Ping-Hui Wang; I-Ming Jou; Wei-Ren Su
Journal:  Arthrosc Tech       Date:  2017-06-05

2.  The modified Norwegian method of biceps tenodesis: how well does it work?

Authors:  Sami Faruqui; Mohammad A Kotob; Courtney C Hanna; Abdullah Foad
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-03       Impact factor: 4.342

Review 3.  Outcomes following long head of biceps tendon tenodesis.

Authors:  Saad M AlQahtani; Ryan T Bicknell
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12

4.  Double on-lay fixation using all suture-type anchor for subpectoral biceps tenodesis has favorable functional outcomes and leads to less cosmetic deformities than single on-lay fixation.

Authors:  Sung-Min Rhee; Ho Yeon Jeong; Kyunghan Ro; Samyak Pancholi; Yong Girl Rhee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-08-13       Impact factor: 4.342

5.  Arthroscopic Single-Portal Suprapectoral Biceps Tenodesis With All-Suture Anchor.

Authors:  Abhishek Kannan; Charles J Cogan; Alan L Zhang
Journal:  Arthrosc Tech       Date:  2022-02-08

6.  Can a Two Simple Stitches Method Provide Secure Fixation Strength in Biceps Tenodesis?: Biomechanical Evaluation of Various Suture Techniques.

Authors:  Tae Min Kim; Myung Ho Shin; Samuel Baek; Dong Ryun Lee; Seok Won Chung
Journal:  Clin Orthop Surg       Date:  2022-06-30

7.  Technique for Type IV SLAP Lesion Repair.

Authors:  Burak Altintas; Rafael Pitta; Erik M Fritz; Brendan Higgins; Peter J Millett
Journal:  Arthrosc Tech       Date:  2018-03-12

8.  Subpectoral Biceps Tenodesis: All-Suture Anchor Onlay Technique.

Authors:  Lucca Lacheta; Andreas B Imhoff; Sebastian Siebenlist; Bastian Scheiderer
Journal:  Arthrosc Tech       Date:  2020-04-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.