Literature DB >> 25272958

Development of a specific immunomagnetic capture-PCR for rapid detection of viable Mycoplasma agalactiae in sheep milk samples.

G Sanna1, V Lecca, A Foddai, S Tola.   

Abstract

AIMS: To develop an immunomagnetic capture (IMC) to detect viable Mycoplasma agalactiae in routine ovine milk samples. METHODS AND
RESULTS: Polyclonal antibodies against two M. agalactiae membrane surface proteins (P80 and P55) were covalently conjugated to magnetic beads (MBs) to form MB-Ab80 and MB-Ab55. Mycoplasma agalactiae cells were captured by a specific antigen-antibody reaction and magnetic separation. Immunomagnetic capture (IMC) was used to isolate and concentrate M. agalactiae in serial decimal dilutions and in artificially contaminated milk to facilitate subsequent detection by PCR. A 375-bp fragment of M. agalactiae was amplified using a pair of M. agalactiae-specific primers in PCR. The limit of detection of IMC-PCR method ranged from 10 to 10(2)  CCU ml(-1) when mycoplasmas were resuspended in PBS and from 10(2) to 10(3)  CCU ml(-1) when mycoplasmas were resuspended in uncontaminated ovine milk. This study also describes the application of IMC-PCR method to test for M. agalactiae in 516 milk samples collected from sheep with suspected contagious agalactia. Its performance was evaluated relative to culture.
CONCLUSIONS: This report has demonstrated for the first time, the effective use of rapid and reliable IMC combined with PCR assay for the detection of viable M. agalactiae. SIGNIFICANCE AND IMPACT OF THE STUDY: The method IMC-PCR provides an alternative to conventional microbiological detection, method and it could be applied to quick detection of M. agalactiae in routine sheep milk samples.
© 2014 The Authors published by John Wiley & Sons Ltd on behalf of Society for Applied Microbiology.

Entities:  

Keywords:  Mycoplasma agalactiae; PCR; antibodies; immunocapture; membrane surface proteins

Mesh:

Substances:

Year:  2014        PMID: 25272958     DOI: 10.1111/jam.12657

Source DB:  PubMed          Journal:  J Appl Microbiol        ISSN: 1364-5072            Impact factor:   3.772


  1 in total

1.  Development of loop-mediated isothermal amplification test for the diagnosis of contagious agalactia in goats.

Authors:  Valsala Rekha; Rajneesh Rana; Prasad Thomas; Konasagara Nagaleekar Viswas; Vijendra Pal Singh; Rajesh Kumar Agarwal; Thachappully Remesh Arun; Kumaragurubaran Karthik; Inbaraj Sophia
Journal:  Trop Anim Health Prod       Date:  2015-01-24       Impact factor: 1.559

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.