Literature DB >> 25268308

A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a prospective cohort study.

Daisy Walter1, Uwe Will2, Andres Sanchez-Yague3, Dirk Brenke4, Jochen Hampe5, Helge Wollny6, Jose Miguel Esteban López-Jamar7, Gertrud Jechart8, Peter Vilmann9, Joan B Gornals10, Sebastian Ullrich11, Martin Fähndrich12, Alberto Herreros de Tejada13, Félix Junquera14, Ferran Gonzalez-Huix15, Peter D Siersema1, Frank P Vleggaar1.   

Abstract

BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the efficacy and safety of this stent in a large cohort. PATIENTS AND METHODS: Patients with a PFC undergoing EUS-guided drainage with this novel stent were prospectively enrolled in this multicenter cohort study.
RESULTS: There were 61 patients: 46 patients (75 %) with walled-off necrosis (WON) and 15 (25 %) with a pancreatic pseudocyst. Stent placement was technically successful in 60 patients (98 %, 95 %CI 95 % - 100 %). Clinical success, defined as resolution of clinical symptoms in combination with a decrease in the PFC size to ≤ 2 cm on imaging, was achieved in 93 % of patients with a pancreatic pseudocyst (95 %CI 77 % - 100 %) and in 81 % of patients with WON (95 %CI 69 % - 94 %). Treatment failure occurred in nine patients (16 %, 95 %CI 6 % - 26 %), including four patients who required surgical intervention. Stent removal was performed in 82 % of patients after a median of 32 days (range 2 - 178) and was rated as easy in all but one patient. In 10 patients, endoscopic stent removal was not performed because of stent migration (n = 3), stent dislodgement during necrosectomy (n = 3), stent removal during surgery (n = 2), or refusal by the patient (n = 2). In total, five major complications were reported (9 %, 95 %CI 2 % - 16 %), including PFC infection (n = 4) and perforation (n = 1).
CONCLUSION: EUS-guided drainage using this novel stent is feasible and the clinical results obtained are promising with a low major complication rate. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2014        PMID: 25268308     DOI: 10.1055/s-0034-1378113

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  64 in total

Review 1.  Endoscopic ultrasonography: Transition towards the future of gastro-intestinal diseases.

Authors:  Stefania De Lisi; Marc Giovannini
Journal:  World J Gastroenterol       Date:  2016-02-07       Impact factor: 5.742

Review 2.  Management of Disconnected Pancreatic Duct Syndrome.

Authors:  Michael Larsen; Richard A Kozarek
Journal:  Curr Treat Options Gastroenterol       Date:  2016-09

3.  The safety and efficacy of a new 20-mm lumen apposing metal stent (lams) for the endoscopic treatment of pancreatic and peripancreatic fluid collections: a large international, multicenter study.

Authors:  Andrea Anderloni; Carlo Fabbri; Jose Nieto; Will Uwe; Markus Dollhopf; José Ramón Aparicio; Manuel Perez-Miranda; Ilaria Tarantino; Alexander Arlt; Frank Vleggaar; Geoffrey Vanbiervliet; Jochen Hampe; Michel Kahaleh; Juan J Vila; Barham K Abu Dayyeh; Andrew C Storm; Alessandro Fugazza; Cecilia Binda; Antoine Charachon; Sergio Sevilla-Ribota; Amy Tyberg; Moran Robert; Sachin Wani; Alessandro Repici; Amrita Sethi; Mouen A Khashab; Rastislav Kunda
Journal:  Surg Endosc       Date:  2020-04-22       Impact factor: 4.584

Review 4.  Management of pancreatic fluid collections: A comprehensive review of the literature.

Authors:  Amy Tyberg; Kunal Karia; Moamen Gabr; Amit Desai; Rushabh Doshi; Monica Gaidhane; Reem Z Sharaiha; Michel Kahaleh
Journal:  World J Gastroenterol       Date:  2016-02-21       Impact factor: 5.742

Review 5.  Endoscopic ultrasound guided interventional procedures.

Authors:  Vishal Sharma; Surinder S Rana; Deepak K Bhasin
Journal:  World J Gastrointest Endosc       Date:  2015-06-10

Review 6.  Outcome of stenting in biliary and pancreatic benign and malignant diseases: A comprehensive review.

Authors:  Benedetto Mangiavillano; Nico Pagano; Todd H Baron; Carmelo Luigiano
Journal:  World J Gastroenterol       Date:  2015-08-14       Impact factor: 5.742

7.  EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP.

Authors:  Rastislav Kunda; Manuel Pérez-Miranda; Uwe Will; Sebastian Ullrich; Dirk Brenke; Markus Dollhopf; Michelle Meier; Alberto Larghi
Journal:  Surg Endosc       Date:  2016-03-11       Impact factor: 4.584

Review 8.  Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis.

Authors:  Tariq Hammad; Muhammad Ali Khan; Yaseen Alastal; Wade Lee; Ali Nawras; Mohammad Kashif Ismail; Michel Kahaleh
Journal:  Dig Dis Sci       Date:  2017-12-27       Impact factor: 3.199

9.  Secured Lumen-Apposing Fully Covered Metallic Stents for Stenoses in Post-Bariatric Surgery Patients.

Authors:  Cem Simsek; Yervant Ichkhanian; Lea Fayad; Kimberly E Steele; Michael A Schweitzer; Katherine Lamond; Kia Vosoughi; Jay Doshi; Tazkia Shah; Andreas Oberbach; Abdulhameed Al-Sabban; Alex Gandsas; Anthony N Kalloo; Mouen A Khashab; Vivek Kumbhari
Journal:  Obes Surg       Date:  2019-08       Impact factor: 4.129

Review 10.  New Advances in the Treatment of Acute Pancreatitis.

Authors:  Mahya Faghih; Christopher Fan; Vikesh K Singh
Journal:  Curr Treat Options Gastroenterol       Date:  2019-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.