Radiation safety consideration during intraoperative radiation therapy.

Paul N Mobit1, Priyadarshini Rajaguru2, Michael Brewer2, Michael Baird2, Satyaseelan Packianathan2, Claus Chunli Yang2.   

Abstract

Using in-house-designed phantoms, the authors evaluated radiation exposure rates in the vicinity of a newly acquired intraoperative radiation therapy (IORT) system: Axxent Electronic Brachytherapy System. The authors also investigated the perimeter radiation levels during three different clinical intraoperative treatments (breast, floor of the mouth and bilateral neck cancer patients). Radiation surveys during treatment delivery indicated that IORT using the surface applicator and IORT using balloons inserted into patient body give rise to exposure rates of 200 mR h(-1), 30 cm from a treated area. To reduce the exposure levels, movable lead shields should be used as they reduce the exposure rates by >95%. The authors' measurements suggest that intraoperative treatment using the 50-kVp X-ray source can be administered in any regular operating room without the need for radiation shielding modification as long as the operators utilise lead aprons and/or stand behind lead shields.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2014        PMID: 25267855     DOI: 10.1093/rpd/ncu292

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

Review 1.  Electronic brachytherapy--current status and future directions.

Authors:  D J Eaton
Journal:  Br J Radiol       Date:  2015-03-06       Impact factor: 3.039

2.  Comparison of Axxent-Xoft, (192)Ir and (60)Co high-dose-rate brachytherapy sources for image-guided brachytherapy treatment planning for cervical cancer.

Authors:  P N Mobit; S Packianathan; R He; C C Yang
Journal:  Br J Radiol       Date:  2015-05-21       Impact factor: 3.039

3.  Feasibility of interstitial stepping-source electronic brachytherapy to locally inoperable tumors.

Authors:  Arne Mathias Ruder; Laurens Inghelram; Frank Schneider; Gustavo R Sarria; Jürgen Hesser; Frederic Bludau; Udo Obertacke; Frederik Wenz; Yasser Abo-Madyan; Frank A Giordano
Journal:  J Contemp Brachytherapy       Date:  2020-10-30

4.  Dosimetric comparison of brachytherapy sources for high-dose-rate treatment of endometrial cancer: (192)Ir, (60)Co and an electronic brachytherapy source.

Authors:  Paul N Mobit; Alex Nguyen; Satyaseelan Packianathan; Rui He; Claus C Yang
Journal:  Br J Radiol       Date:  2016-01-08       Impact factor: 3.039

5.  A Novel Radiotherapy Approach for Keloids with Intrabeam.

Authors:  Xiaojing Yang; Yuhui Shao; Weiwei Yu; Xiulong Zhang; Yi Sun; Lihua Zhang; Hongling Li; Xinmiao Yang; Jie Fu
Journal:  Biomed Res Int       Date:  2019-07-22       Impact factor: 3.411

6.  Preclinical Evaluation of Intraoperative Low-Energy Photon Radiotherapy Using Spherical Applicators in Locally Advanced Prostate Cancer.

Authors:  François Buge; Sophie Chiavassa; Chloé Hervé; Jérôme Rigaud; Grégory Delpon; Stéphane Supiot
Journal:  Front Oncol       Date:  2015-09-15       Impact factor: 6.244