A dynamic attenuator improves spectral imaging with energy-discriminating, photon counting detectors.

Scott S Hsieh, Norbert J Pelc.   

Abstract

Energy-discriminating, photon counting (EDPC) detectors have high potential in spectral imaging applications but exhibit degraded performance when the incident count rate approaches or exceeds the characteristic count rate of the detector. In order to reduce the requirements on the detector, we explore the strategy of modulating the X-ray flux field using a recently proposed dynamic, piecewise-linear attenuator. A previous paper studied this modulation for photon counting detectors but did not explore the impact on spectral applications. In this work, we modeled detection with a bipolar triangular pulse shape (Taguchi et al., 2011) and estimated the Cramer-Rao lower bound (CRLB) of the variance of material selective and equivalent monoenergetic images, assuming deterministic errors at high flux could be corrected. We compared different materials for the dynamic attenuator and found that rare earth elements, such as erbium, outperformed previously proposed materials such as iron in spectral imaging. The redistribution of flux reduces the variance or dose, consistent with previous studies on benefits with conventional detectors. Numerical simulations based on DICOM datasets were used to assess the impact of the dynamic attenuator for detectors with several different characteristic count rates. The dynamic attenuator reduced the peak incident count rate by a factor of 4 in the thorax and 44 in the pelvis, and a 10 Mcps/mm (2) EDPC detector with dynamic attenuator provided generally superior image quality to a 100 Mcps/mm (2) detector with reference bowtie filter for the same dose. The improvement is more pronounced in the material images.

Entities:  

Mesh:

Year:  2014        PMID: 25265628     DOI: 10.1109/TMI.2014.2360381

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Improving pulse detection in multibin photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2016-06-01

2.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

3.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07

4.  A prototype piecewise-linear dynamic attenuator.

Authors:  Scott S Hsieh; Mark V Peng; Christopher A May; Picha Shunhavanich; Dominik Fleischmann; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2016-06-10       Impact factor: 3.609

5.  Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.

Authors:  Katsuyuki Taguchi
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-06-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.