Literature DB >> 25264180

The insertion technique of translaminar screws in the thoracic spine: computed tomography and cadaveric validation.

Woojin Cho1, Jason T Le2, Adam L Shimer2, Brian C Werner2, John A Glaser3, Francis H Shen4.   

Abstract

BACKGROUND CONTEXT: Translaminar screws can be a good salvage technique in some cases of severe deformities, infection, tumor, osteoporosis, and revision cases with altered anatomy. To our knowledge, the insertion technique for translaminar screws in the thoracic spine has not been studied.
PURPOSE: To suggest a safe insertion technique of translaminar screws in the thoracic spine. STUDY
DESIGN: A cadaveric study.
METHODS: Fifteen cadaveric spines were harvested from T1 to T12, and 1-mm computed tomography (CT) scans and three-dimensional reconstructions were obtained to rule out any bony anomaly. Eleven of the cadaveric spines were separated at each level from T1 to T12 (Group S) and four were not separated (Group N-S). Translaminar screws were inserted into every level along the trajectories proposed by the previous studies. The screw diameter was determined based on the reference article. For T1-T6, the screw diameter selected was 4 mm, and for T7-T12, a 3.5-mm diameter screw was used instead. The entry point for the 1° screw was at a distance equal to the diameter of the desired screw above the inferior margin of the spinolaminar junction. To create the trajectory, a drill guide was inserted at the entry point and directed toward the middle portion of the base of the transverse process of the contralateral side and was followed carefully to not break the inner/outer cortex of the lamina. The length of the drilled hole, representing the trajectory of the screw made by the drill guide, was measured, and the 1° screws were inserted according to the length measured. The entry point for the 2° screw was at a distance equal to the diameter of the screw below the superior margin of the base of the spinous process and lamina junction. The drill guide was pointed toward the inferior angle of the contralateral junction of the rib and the vertebra along the slope of the contralateral lamina. The 2° screw was inserted in the same manner as previously described. The 2° screw diameter was downsized if there was not enough space because of the 1° screw. For each vertebra from the 11 separated cadaveric spines, inner or outer cortex breakage was checked visually. For the remaining four nonseparated spines, CT scans were used to find any inner or outer cortex breakage.
RESULTS: Thirty-three vertebral levels were abandoned from Group S because of altered anatomy (eg, fusion, fracture during separation, anatomical anomaly of having only 11 thoracic spine segments). Out of 147 vertebral levels, there was no vertebra that did not allow screw insertion. No specimen required using smaller diameter 2° screw because of blockage of the 1° screw. There was no cortical breakage by the screws in Group S. In Group N-S, CT scan showed four inner cortex breakages and three outer cortex breakages, all of which were slight cortical breakages. There were no facet injuries due to the screws in Group N-S. There was no blockage of the ribs during screw placement in all specimens, and the drill guide could lean against the rib for guidance because the angle of the rib and the opposite lamina tended to be the same.
CONCLUSIONS: Translaminar screws can be inserted relatively safely in the thoracic spine. For the 1° translaminar screw, the entry point is at a distance equal to the diameter of the desired screw superior to the inferior margin of the lamina-spinous process junction. The trajectory should be targeted toward the center of the base of the contralateral transverse process. For the 2° translaminar screw, the entry point is at a distance equal to the diameter of the desired screw below the superior margin of lamina-spinous process junction, and the target is the inferior angle of the junction of the rib and vertebra on the contralateral side.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CT; Cadaveric; Insertion technique; Thoracic spine; Translaminar screws; Validation

Mesh:

Year:  2014        PMID: 25264180     DOI: 10.1016/j.spinee.2014.09.013

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  4 in total

1.  Ideal T1 laminar screw fixation based on computed tomography morphometry.

Authors:  Xiao-Bo Wang; Xin Zheng; Hou-Qing Long; Wen-Li Chen; Xing Cheng; Yang-Liang Huang; Jing-Hui Xu
Journal:  BMC Musculoskelet Disord       Date:  2017-06-02       Impact factor: 2.362

2.  The risk of translaminar screw fixation to the transverse foramen of the lower cervical spine: a computed tomography study.

Authors:  Ganggang Kong; Wei Ji; Zucheng Huang; Junhao Liu; Jianting Chen; Qingan Zhu
Journal:  Sci Rep       Date:  2017-04-21       Impact factor: 4.379

Review 3.  Biomechanics and Clinical Application of Translaminar Screws Fixation in Spine: A Review of the Literature.

Authors:  Jimmy J Chan; Nicholas Shepard; Woojin Cho
Journal:  Global Spine J       Date:  2018-04-19

Review 4.  Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review.

Authors:  Ulrich J Spiegl; Georg Osterhoff; Philipp Bula; Frank Hartmann; Max J Scheyerer; Klaus J Schnake; Bernhard W Ullrich
Journal:  Eur J Trauma Emerg Surg       Date:  2020-12-02       Impact factor: 3.693

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.