| Literature DB >> 25263035 |
Michael E Snyder1, Mauricio A Perez2.
Abstract
UNLABELLED: We present a technique for posterior chamber intraocular lens (IOL) scleral suturing for the management of aphakia, which includes the use of a needleless Gore-Tex CV-8 suture to create a girth hitch around both IOL fixation eyelets using microinstruments. This technique avoids intraocular needle manipulation, provides long-term IOL stability, avoids both passive and torque-induced IOL tilt, and enables fine tuning of the intraoperative IOL centration using the Purkinje reflexes. FINANCIAL DISCLOSURE: Dr. Snyder is a consultant to Alcon Laboratories, Inc., Microsurgical Technology, Haag-Streit AG, and Humanoptics AG. Dr. Perez has no financial or proprietary interest in any material or method mentionedEntities:
Mesh:
Substances:
Year: 2014 PMID: 25263035 DOI: 10.1016/j.jcrs.2014.08.022
Source DB: PubMed Journal: J Cataract Refract Surg ISSN: 0886-3350 Impact factor: 3.351