Ultrasonic evaluation of dental implant osseointegration.

Romain Vayron1, Emmanuel Soffer2, Fani Anagnostou2, Guillaume Haïat3.   

Abstract

Dental implants are widely used for oral rehabilitation. However, there remain risks of failure which are difficult to anticipate and depend on the implant osseointegration. The objective of this in vivo study is to determine the variation of the echographic ultrasonic response of a dental implant to bone healing around the implant interface. Twenty one dental implants were inserted in the femur of seven New Zealand white rabbits. Two animals were sacrificed after a healing duration of two weeks, three animals after six weeks and six animals after eleven weeks. The 10 MHz ultrasonic response of the implant was measured just after the implantation using a dedicated device positioned at the emerging surface of each dental implant. The measurements were realized again before the sacrifice with the same device. An indicator I˜ was derived based on the amplitude of the rf signal obtained for each configuration. The bone-Implant Contact (BIC) ratio was determined by histological analyses. The average value of the relative variation of the indicator I˜ obtained after initial surgery and after the corresponding healing period varies between 7% and 40%. A Kruskal-Wallis test (p<0.01) revealed a significant decrease of the value of the indicator I˜ as function of healing time. The indicator I˜ was significantly correlated (R(2)=0.45) with the BIC ratio. The results show that the ultrasonic response of a dental implant varies significantly as a function of healing time, which paves the way for the development of a new quantitative ultrasound (QUS) method in oral implantology.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Animal model; Dental implant; Osseointegration; Quantitative ultrasound

Mesh:

Substances:

Year:  2014        PMID: 25262877     DOI: 10.1016/j.jbiomech.2014.07.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

Authors:  Vaishnavi Bhaskar; Hsun-Liang Chan; Mark MacEachern; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2018-06-06       Impact factor: 2.419

2.  Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface.

Authors:  Maria Letizia Raffa; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

Review 3.  Quantitative Ultrasound for Nondestructive Characterization of Engineered Tissues and Biomaterials.

Authors:  Diane Dalecki; Karla P Mercado; Denise C Hocking
Journal:  Ann Biomed Eng       Date:  2015-11-18       Impact factor: 3.934

4.  Evaluation of the effects of topically applied simvastatin on titanium implant osseointegration.

Authors:  Serkan Dundar; Alihan Bozoglan
Journal:  J Oral Biol Craniofac Res       Date:  2020-04-17

5.  Piezoelectric Sensor to Measure Soft and Hard Stiffness with High Sensitivity for Ultrasonic Transducers.

Authors:  Yan-Rui Li; Chih-Chung Su; Wen-Jin Lin; Shuo-Hung Chang
Journal:  Sensors (Basel)       Date:  2015-06-11       Impact factor: 3.576

6.  Elastography of the bone-implant interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Didier Geiger; Guillaume Haïat
Journal:  Sci Rep       Date:  2019-10-02       Impact factor: 4.379

7.  Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena.

Authors:  M Fraulob; R Vayron; S Le Cann; B Lecuelle; Y Hériveaux; H Albini Lomami; C H Flouzat Lachaniette; G Haïat
Journal:  Sci Rep       Date:  2020-12-15       Impact factor: 4.379

8.  Evaluation of failed implants and reimplantation at sites of previous dental implant failure: survival rates and risk factors.

Authors:  Yu-Seon Park; Bo-Ah Lee; Seong-Ho Choi; Young-Taek Kim
Journal:  J Periodontal Implant Sci       Date:  2022-06       Impact factor: 2.086

9.  Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration.

Authors:  Romain Vayron; Vu-Hieu Nguyen; Benoît Lecuelle; Hugues Albini Lomami; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Journal:  Sensors (Basel)       Date:  2018-05-02       Impact factor: 3.576

Review 10.  Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives.

Authors:  Elisabetta M Zanetti; Giulia Pascoletti; Michele Calì; Cristina Bignardi; Giordano Franceschini
Journal:  Biosensors (Basel)       Date:  2018-07-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.