Literature DB >> 25261173

Effect of hydroxyapatite coating on the radio-clinical results of a grit-blasted titanium alloy femoral taper. A case-control study of 198 cementless primary total hip arthroplasty with the Alloclassic™ system.

C Delaunay1.   

Abstract

BACKGROUND: The effect of hydroxyapatite (HA) coating on the fixation of a cementless femoral stem is discussed, in particular in cases of primary fixation with geometrically stable components. Therefore, we performed a comparative retrospective study of a series of Alloclassic-SL™ stems to: 1) present the long-term results and 2) evaluate the contribution, if any, of proximal HA coating. HYPOTHESES: Long-term cementless press-fit ("flat wedge-shaped") fixation is reliable and HA coating only improves the radiological results of the proximal bone-prosthesis interface.
MATERIALS AND METHODS: One hundred and ninety-eight Alloclassic total hip arthroplasties were performed in 179 patients, mean age 66 years old (22-85), including 105 with proximal HA coating and 93 with the original grit-blast coating. One hundred and ninety-three hips were analyzed after a mean follow-up of 9.8 years (1-24 years).
RESULTS: Results were excellent or good in 184 hips (95%) with no significant difference between the 2 groups (Merle d'Aubigné≥16 for 89/92 (98%) without HA compared to 95/101 (94%) with HA P=0.59). Radiographic signs of stable osseointegration were observed in 173 hips (90% of the cases). HA coating significantly improved the radiographic results of the proximal bone-implant interface: (42/92 (46%) of the stems without HA had proximal radiolucencies in zones 1 and 7 compared to 4/101 (4%) with HA (P=0.0001)). Polyethylene wear>0.1 mm/year was observed in 6 hips (3%) including 1/101 (1%) in the group with HA versus 5/92 (5.4%) without HA (P=0.17). One intra-operative femoral fracture occurred and there were 9 dislocations in the first 3 postoperative months (4.5%). The main cause of revision surgery was recurrent dislocation (11/17 cases). The "revision per-100 observed-femoral component years" was 0.10 in both groups and survival for aseptic loosening of the stem was 100% (95% CI=73.2% to 100%) at 20 years.
CONCLUSION: This study shows that secondary fixation by osseointegration of a straight standard grit-blasted titanium alloy non-anatomical implant is reliable. Possible proximal fibrous encapsulation, which is reduced by HA coating, but especially conventional polyethylene wear, were the main limitations of this system. LEVEL OF EVIDENCE: III retrospective case-control study.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Alloclassic system; Cementless stem; Hydroxyapatite; Total hip arthroplasty

Mesh:

Substances:

Year:  2014        PMID: 25261173     DOI: 10.1016/j.otsr.2014.07.010

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  6 in total

Review 1.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

2.  Fully hydroxyapatite-coated compaction broached and triple-tapered stem may reduce the risk of stress shielding after primary total hip arthroplasty.

Authors:  Yuichi Kuroda; Shingo Hashimoto; Shinya Hayashi; Naoki Nakano; Takaaki Fujishiro; Takafumi Hiranaka; Ryosuke Kuroda; Tomoyuki Matsumoto
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-23       Impact factor: 3.067

3.  Long-term bone remodelling around 'legendary' cementless femoral stems.

Authors:  Charles Rivière; Guido Grappiolo; Charles A Engh; Jean-Pierre Vidalain; Antonia-F Chen; Nicolas Boehler; Jihad Matta; Pascal-André Vendittoli
Journal:  EFORT Open Rev       Date:  2018-02-26

4.  Biological Safety Evaluation and Surface Modification of Biocompatible Ti-15Zr-4Nb Alloy.

Authors:  Yoshimitsu Okazaki; Shin-Ichi Katsuda
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

5.  Real-Time Protein and Cell Binding Measurements on Hydroxyapatite Coatings.

Authors:  A M Vilardell; N Cinca; A Jokinen; N Garcia-Giralt; S Dosta; I G Cano; J M Guilemany
Journal:  J Funct Biomater       Date:  2016-08-27

6.  5-Year Clinical and Radiographic Results of the Direct Anterior Approach for Total Hip Arthroplasty Using a Collared Cementless Femoral Short-Stem Prosthesis.

Authors:  Ali Darwich; Kim Pankert; Andreas Ottersbach; Marcel Betsch; Sascha Gravius; Mohamad Bdeir
Journal:  J Clin Med       Date:  2022-01-11       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.