Literature DB >> 25259550

Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation.

Paul-Rolf Preussner1, Peter Hoffmann, Jochen Wahl.   

Abstract

PURPOSE: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness.
MATERIALS AND METHODS: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences.
RESULTS: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 ± 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3-6 D at 90, 0.38 D at 89° and 0.28 D at 91° (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81° from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis.
CONCLUSION: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.

Entities:  

Keywords:  Astigmatism; keratoconus; posterior corneal surface; toric IOL calculation; vector differences

Mesh:

Year:  2014        PMID: 25259550     DOI: 10.3109/02713683.2014.959708

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  10 in total

1.  The Impact of Changes in Corneal Back Surface Astigmatism on the Residual Astigmatic Refractive Error following Routine Uncomplicated Phacoemulsification.

Authors:  Larysa Tutchenko; Sudi Patel; Oleksiy Voytsekhivskyy; Mykhailo Skovron; Olha Horak
Journal:  J Ophthalmol       Date:  2020-07-22       Impact factor: 1.909

2.  Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient.

Authors:  Xue-Fei Song; Achim Langenbucher; Zisis Gatzioufas; Berthold Seitz; Moatasem El-Husseiny
Journal:  Int J Ophthalmol       Date:  2016-06-18       Impact factor: 1.779

Review 3.  Spotlight on the Corneal Back Surface Astigmatism: A Review.

Authors:  Sudi Patel; Larysa Tutchenko
Journal:  Clin Ophthalmol       Date:  2021-07-26

4.  Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power.

Authors:  C Kern; L El Kaissi; K Kortuem; M Shajari; E Vounotrypidis; A Langenbucher; S Priglinger; W J Mayer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-20       Impact factor: 3.117

5.  Changes in Anterior, Posterior, and Total Corneal Astigmatism after Descemet Membrane Endothelial Keratoplasty.

Authors:  Maged Alnawaiseh; Lars Zumhagen; André Rosentreter; Nicole Eter
Journal:  J Ophthalmol       Date:  2017-05-02       Impact factor: 1.909

6.  Comparison of corneal elevation and pachymetry measurements made by two state of the art corneal tomographers with different measurement principles.

Authors:  Simon Schröder; Achim Langenbucher; Jens Schrecker
Journal:  PLoS One       Date:  2019-10-16       Impact factor: 3.240

7.  Performance of Zernike polynomials in reconstructing raw-elevation data captured by Pentacam HR, Medmont E300 and Eye Surface Profiler.

Authors:  Yueying Wei; Bernardo T Lopes; Ashkan Eliasy; Richard Wu; Arwa Fathy; Ahmed Elsheikh; Ahmed Abass
Journal:  Heliyon       Date:  2021-12-18

8.  Accuracy of OCT-derived net corneal astigmatism measurement.

Authors:  Clara Llorens-Quintana; Elias Pavlatos; Omkar Thaware; Seema Gupta; Daniel Gradin; Denzil Romfh; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

9.  Precision and refractive predictability of a new nomogram for femtosecond laser-assisted corneal arcuate incisions.

Authors:  Jascha A Wendelstein; Peter C Hoffmann; Siegfried Mariacher; Tina Wingert; Nino Hirnschall; Oliver Findl; Matthias Bolz
Journal:  Acta Ophthalmol       Date:  2021-02-24       Impact factor: 3.988

10.  The Castrop formula for calculation of toric intraocular lenses.

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Johannes Weisensee; Jascha Wendelstein; Peter Hoffmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-07-08       Impact factor: 3.117

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.