Monitoring the press-fit insertion of an acetabular cup by impact measurements: influence of bone abrasion.

Adrien Michel1, Romain Bosc1, Vincent Mathieu1, Philippe Hernigou2, Guillaume Haiat3.   

Abstract

Press-fit procedures used for the insertion of cementless hip prostheses aim at obtaining optimal implant primary stability. We have previously used the measurement of impact duration to follow the insertion of the acetabular cup implant within bone tissue. The aim of this study was to investigate the variation of the value of the impact momentum due to successive insertions of the acetabular cup into bone tissue. The results obtained with impact momentum and contact duration measurements were compared. A total of 10 bovine bone samples were subjected to three successive procedures consisting of 10 reproducible impacts (3.5 kg falling 40 mm). Each procedure aimed at inserting the acetabular cup implant into the same bone cavity. The time variation of force during each impact was recorded by a force sensor, allowing the measurement of the impact duration (I 1) and momentum (I 2). The value of I 2 increased as a function of the impact number and reached a constant value after N 2 = 5.07 ± 1.31 impacts. Moreover, statistical analyses show that N 2 decreased significantly as a function of the number of experiments, which may be due to abrasion phenomena at the bone-implant interface. Abrasion phenomena led to a faster insertion of the acetabular cup when the implant had been previously inserted into the same bone cavity. An empirical analytical model considering a flat punch configuration to model the bone-implant contact conditions was used to understand the trend of the variation of I 2 during the insertion of the acetabular cup. The measurement of the force during impacts is useful to assess the bone-implant interface properties, but needs to be validated in the clinic to be useful for orthopaedic surgeons intra-operatively. © IMechE 2014.

Entities:  

Keywords:  Acetabular cup implant; bone; hip prosthesis; impact; vibration analysis

Mesh:

Year:  2014        PMID: 25258009     DOI: 10.1177/0954411914552433

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

2.  History of bone acoustic in fracture diagnosis: crepitus in antiquity; bone percussion with Auenbrugger; bone auscultation with Laennec and Lisfranc; monitoring cementless hip arthroplasty fixation with acoustic and sensor.

Authors:  Philippe Hernigou
Journal:  Int Orthop       Date:  2022-04-22       Impact factor: 3.479

3.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

4.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.