Calculation of limits for significant bidirectional changes in two or more serial results of a biomarker based on a computer simulation model.

Flemming Lund1, Per Hyltoft Petersen2, Callum G Fraser3, György Sölétormos4.   

Abstract

BACKGROUND: Reference change values provide objective tools to assess the significance of a change in two consecutive results of a biomarker from an individual. However, in practice, more results are usually available and using the reference change value concept on more than two results will increase the number of false positive results.
METHODS: A computer simulation model was developed using Excel. Based on 10,000 simulated measurements among healthy individuals, a series of up to 20 results of a biomarker from each individual was generated using different values for the within-subject biological variation plus the analytical variation. Each new result in this series was compared to the initial result. These successive serial differences were computed to give limits for significant bidirectional changes with constant cumulated maximum probabilities of 95% (p < 0.05) and 99% (p < 0.01).
RESULTS: From an individual factors used to multiply the first result were calculated to create limits for constant cumulated significant changes. The factors were shown to become a function of the number of results included and the total coefficient of variation.
CONCLUSIONS: The first result should be multiplied by the appropriate factors for increase and decrease to give the limits for a significant bidirectional change in several consecutive measurements.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Keywords:  False positives; initial concentration; log-normal (Gaussian) distribution; monitoring; normal (Gaussian) distribution; reference change values

Mesh:

Substances:

Year:  2014        PMID: 25249664     DOI: 10.1177/0004563214555163

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  2 in total

Review 1.  Acute Kidney Injury: Diagnostic Approaches and Controversies.

Authors:  Konstantinos Makris; Loukia Spanou
Journal:  Clin Biochem Rev       Date:  2016-12

2.  Reference change values in concentrations of urinary and salivary biomarkers of exposure and mouth level exposure in individuals participating in an ambulatory smoking study.

Authors:  Oscar M Camacho; Johan Sommarström; Krishna Prasad; Anthony Cunningham
Journal:  Pract Lab Med       Date:  2016-05-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.