Literature DB >> 25249613

Functional centre of the upper eyelid: the optimal point for eyelid lifting in ptosis surgery.

Chang Yeom Kim1, Byeong Jae Son2, Sang Yeul Lee1.   

Abstract

AIMS: To establish the novel concept of a functional eyelid centre to determine the optimal point for eyelid lifting in ptosis surgery.
METHODS: This was a prospective study of 112 patients with congenital ptosis. The functional eyelid centre was defined as the point where the eyelid contour showed the best appearance when the upper eyelid was lifted manually. In patients who underwent frontalis suspension surgery using silicone rods, the postoperative outcome was assessed according to the fixation point of the rod.
RESULTS: The average horizontal fissure width and the distance from the medial canthus to the mid-pupillary line were 21.9 and 10.1 mm, respectively. The functional eyelid centre was located 4.28±0.98 mm temporal to the mid-pupillary line. The outcomes of silicone rod surgeries were excellent when the rod was fixated 4.4 mm nasal and 3.9 mm temporal from the functional eyelid centre. These positions corresponded to 0.1 mm nasal and 8.2 mm temporal from the mid-pupillary line.
CONCLUSIONS: The functional eyelid centre was located slightly temporal to the mid-pupillary line. A better eyelid contour in ptosis surgery is produced when eyelid lifting is centred around the functional eyelid centre. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Entities:  

Keywords:  Eye Lids; Treatment Surgery

Mesh:

Substances:

Year:  2014        PMID: 25249613     DOI: 10.1136/bjophthalmol-2014-305101

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  3 in total

1.  Comparison of two- and three-point sutures for advancing the levator aponeurosis in Asian eyelids.

Authors:  Y S Kim; J S Yoon; S Y Jang
Journal:  Eye (Lond)       Date:  2015-06-26       Impact factor: 3.775

Review 2.  Suspensory Materials for Surgery of Blepharoptosis: A Systematic Review of Observational Studies.

Authors:  Elena Pacella; Daniele Mipatrini; Fernanda Pacella; Giulia Amorelli; Andrea Bottone; Gianpaolo Smaldone; Paolo Turchetti; Giuseppe La Torre
Journal:  PLoS One       Date:  2016-09-15       Impact factor: 3.240

3.  Comparing the symmetry of upper eyelid following unilateral ptosis correction.

Authors:  Hasan Aytogan; Emre Ayıntap
Journal:  BMC Ophthalmol       Date:  2021-12-20       Impact factor: 2.209

  3 in total