Literature DB >> 25247956

Contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-recalled echo sequence versus conventional fat-suppressed contrast-enhanced T1-weighted studies of the head and neck.

Xin Wu1, Eytan Raz, Tobias K Block, Christian Geppert, Mari Hagiwara, Mary T Bruno, Girish M Fatterpekar.   

Abstract

OBJECTIVE: Traditional fat-suppressed T1-weighted spin-echo or turbo spin-echo (TSE) sequences (T1-weighted images) may be degraded by motion and pulsation artifacts in head-and-neck studies. Our purpose is to evaluate the role of a fat-suppressed T1-weighted 3D radial gradient-recalled echo sequence (radial-volumetric interpolated breath-hold examination [VIBE]) in the head and neck as compared with standard contrast-enhanced fat-suppressed T1-weighted images.
MATERIALS AND METHODS: We retrospectively evaluated 21 patients (age range, 9-67 years) who underwent head-and-neck MRI at 1.5 T. Both contrast-enhanced radial-VIBE and conventional fat-suppressed TSE contrast-enhanced T1-weighted imaging were performed. Two radiologists evaluated multiple parameters of image quality, graded on a 5-point scale. Mixed-model analysis of variance and interobserver variability assessment were performed.
RESULTS: The following parameters were scored as significantly better for the contrast-enhanced radial-VIBE sequence than for conventional contrast-enhanced T1-weighted imaging: overall image quality (p < 0.0001), degree of fat suppression (p = 0.006), mucosal enhancement (p = 0.004), muscle edge clarity (p = 0.049), vessel clarity (p < 0.0001), respiratory motion artifact (p = 0.002), pulsation artifact (p < 0.0001), and lesion edge sharpness (p = 0.004). Interobserver agreement in qualitative evaluation of the two sequences showed fair-to-good agreement for the following variables: overall image quality (intraclass correlation coefficient [ICC], 0.779), degree of fat suppression (ICC, 0.716), mucosal enhancement (ICC, 0.693), muscle edge clarity (ICC, 0.675), respiratory motion artifact (ICC, 0.516), lesion enhancement (ICC, 0.410), and lesion edge sharpness (ICC, 0.538). Excellent agreement was shown for vessel clarity (ICC, 0.846) and pulsation artifact (ICC, 0.808).
CONCLUSION: The radial-VIBE sequence is a viable motion-robust improvement on the conventional fat-suppressed T1-weighted sequence.

Entities:  

Keywords:  MRI; contrast enhanced; neck; radial–volumetric interpolated breath-hold examination

Mesh:

Substances:

Year:  2014        PMID: 25247956     DOI: 10.2214/AJR.13.11729

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Comparison between free-breathing radial VIBE on 3-T MRI and endoscopic ultrasound for preoperative T staging of resectable oesophageal cancer, with histopathological correlation.

Authors:  Jinrong Qu; Hongkai Zhang; Zhaoqi Wang; Fengguang Zhang; Hui Liu; Zhidan Ding; Yin Li; Jie Ma; Zhongxian Zhang; Shouning Zhang; Yafeng Dong; Lina Jiang; Wei Zhang; Robert Grimm; Berthold Kiefer; Ihab R Kamel; Jianjun Qin; Hailiang Li
Journal:  Eur Radiol       Date:  2017-08-10       Impact factor: 5.315

2.  Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma.

Authors:  Shivani Ahlawat; Carol Morris; Laura M Fayad
Journal:  Skeletal Radiol       Date:  2016-02-20       Impact factor: 2.199

3.  Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity.

Authors:  Laura Heacock; Yiming Gao; Samantha L Heller; Amy N Melsaether; James S Babb; Tobias K Block; Ricardo Otazo; Sungheon G Kim; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2016-11-17       Impact factor: 4.813

4.  Mandibular canal visibility using a plain volumetric interpolated breath-hold examination sequence in MRI.

Authors:  Chutamas Deepho; Hiroshi Watanabe; Junichiro Sakamoto; Tohru Kurabayashi
Journal:  Dentomaxillofac Radiol       Date:  2017-10-20       Impact factor: 2.419

Review 5.  Recent advances in MRI of the head and neck, skull base and cranial nerves: new and evolving sequences, analyses and clinical applications.

Authors:  Philip Touska; Steve E J Connor
Journal:  Br J Radiol       Date:  2019-09-24       Impact factor: 3.039

6.  Visualization of the normal appendix in children: feasibility of a single contrast-enhanced radial gradient recalled echo MRI sequence.

Authors:  Shailee V Lala; Naomi Strubel; Nicole Nocera; Mark E Bittman; Nancy R Fefferman
Journal:  Pediatr Radiol       Date:  2019-02-19

7.  Differentiation of Jugular Foramen Paragangliomas versus Schwannomas Using Golden-Angle Radial Sparse Parallel Dynamic Contrast-Enhanced MRI.

Authors:  A Pires; G Nayak; E Zan; M Hagiwara; O Gonen; G Fatterpekar
Journal:  AJNR Am J Neuroradiol       Date:  2021-09-09       Impact factor: 4.966

8.  Radial spoiled gradient T1 weighted imaging of the internal auditory canal: Is Scarpa's ganglion now an expected finding and source of fundal enhancement?

Authors:  Kamran Munawar; Eytan Raz; Seena Dehkharghani; Girish M Fatterpekar; Tobias K Block; Yvonne W Lui
Journal:  Neuroradiol J       Date:  2022-01-11

9.  Preoperative T Staging of Potentially Resectable Esophageal Cancer: A Comparison between Free-Breathing Radial VIBE and Breath-Hold Cartesian VIBE, with Histopathological Correlation.

Authors:  Fengguang Zhang; Jinrong Qu; Hongkai Zhang; Hui Liu; Jianjun Qin; Zhidan Ding; Yin Li; Jie Ma; Zhongxian Zhang; Zhaoqi Wang; Jianwei Zhang; Shouning Zhang; Yafeng Dong; Robert Grimm; Ihab R Kamel; Hailiang Li
Journal:  Transl Oncol       Date:  2017-03-19       Impact factor: 4.243

10.  Fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI for predicting small node metastases in patients with rectal cancer.

Authors:  Yan Chen; Xinyue Yang; Ziqiang Wen; Baolan Lu; Xiaojuan Xiao; Bingqi Shen; Shenping Yu
Journal:  Cancer Imaging       Date:  2018-05-21       Impact factor: 3.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.