Literature DB >> 25246145

Variability in target delineation for cavernous sinus meningioma and anaplastic astrocytoma in stereotactic radiosurgery with Leksell Gamma Knife Perfexion.

Helena Sandström1, Håkan Nordström, Jonas Johansson, Per Kjäll, Hidefumi Jokura, Iuliana Toma-Dasu.   

Abstract

BACKGROUND: Radiosurgery clinical practice relays on empirical observations and the experience of the practitioners involved in determining and delineating the target and therefore variability in target delineation might be expected for all the radiosurgery approaches, independent of the technique and the equipment used for delivering the treatment. The main aim of this study was to quantify the variability of target delineation for two radiosurgery targets expected to be difficult to delineate. The secondary aim was to investigate the dosimetric implications with respect to the plan conformity. The primary aim of the study has therefore a very general character, not being bound to one specific radiosurgery technique.
MATERIALS AND METHODS: Twenty radiosurgery centers were asked to delineate one cavernous sinus meningioma and one astrocytoma and to plan the treatments for Leksell Gamma Knife Perfexion. The analysis of the delineated targets was based on the calculated 50 % agreement volume, AV50. The AV50 was compared to each delineated target by the concordance index and discordance index. The differences in location, size, and shape of the delineated targets were also analyzed using the encompassing volume compared to the common volume, i.e., the AV100, of all delineated structures.
RESULTS: Target delineation led to major differences between the participating centers and therefore the AV50 was small in comparison to each delineated target volume. For meningioma, the AV50 was 5.90 cm(3), the AV100 was 2.60 cm(3), and the encompassing volume was 13.14 cm(3). For astrocytoma, the AV50 was 2.06 cm(3) while the AV100 was extremely small, only 0.05 cm(3), and the encompassing volume was 43.27 cm(3). These variations translate into corresponding discrepancies in plan conformity.
CONCLUSIONS: Significant differences in shape, size, and location between the targets included in this study were identified and therefore the clinical implications of these differences should be further investigated.

Entities:  

Mesh:

Year:  2014        PMID: 25246145     DOI: 10.1007/s00701-014-2235-1

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  4 in total

1.  Dependence of volume calculation and margin growth accuracy on treatment planning systems for stereotactic radiosurgery.

Authors:  David J Eaton; Kevin Alty
Journal:  Br J Radiol       Date:  2017-10-12       Impact factor: 3.039

2.  Variability in spine radiosurgery treatment planning - results of an international multi-institutional study.

Authors:  André Toussaint; Anne Richter; Frederick Mantel; John C Flickinger; Inga Siiner Grills; Neelam Tyagi; Arjun Sahgal; Daniel Letourneau; Jason P Sheehan; David J Schlesinger; Peter Carlos Gerszten; Matthias Guckenberger
Journal:  Radiat Oncol       Date:  2016-04-18       Impact factor: 3.481

3.  Evaluation of the stability of the stereotactic Leksell Frame G in Gamma Knife radiosurgery.

Authors:  Alvaro Rojas-Villabona; Katherine Miszkiel; Neil Kitchen; Rolf Jäger; Ian Paddick
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

4.  Improved dosimetric accuracy with semi-automatic contour propagation of organs-at-risk in glioblastoma patients undergoing chemoradiation.

Authors:  Sangjune Lee; James Stewart; Young Lee; Sten Myrehaug; Arjun Sahgal; Mark Ruschin; Chia-Lin Tseng
Journal:  J Appl Clin Med Phys       Date:  2019-10-31       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.