Nilgün Güdücü1, Uzay Görmüş2, Ebru İlhan Güner3, Omer Güzel3, Zehra Neşe Kavak4. 1. Department of Obstetrics and Gynecology, İstanbul Bilim University Istanbul, Turkey. 2. Department of Biochemistry, İstanbul Bilim University Istanbul, Turkey. 3. Centro Laboratories Gursel Mahallesi, Kagithane Caddesi, 14/3 Kagithane, Istanbul, Turkey. 4. Department of Obstetrics and Gynecology, Marmara University School of Medicine, Marmara University Hospital Istanbul, Turkey.
Abstract
AIM: Quadruple test is used for Down's syndrome screening in the second trimester of pregnancy. The aim of this study was to investigate differences in quadruple test parameters between pregnancies achieved by assisted reproductive treatments (ART) and spontaneous conception. MATERIALS AND METHODS: We retrospectively compared levels of alfa-fetoprotein (AFP), unconjugated Estriol (uE3), inhibin-A and hCG and also screen positive test results. RESULTS: Levels of all quadruple test parameters were statistically significantly increased in ART pregnancies when compared to spontaneous pregnancies, AFP was 1.4±0.74 and 1.16±0.53, (p=0.001), uE3 was 1.10±0.37 and 1.00±0.28, (p=0.004), hCG was 1.56±1.04 and 1.26±0.76, (p=0.001), inhibin A was 1.38±0.76 and 1.08±0.57, (p=0.001), screen positive tests were nearly doubled (4.8% and 8.4%). CONCLUSIONS: Increased screen positive test results and quadruple test parameters in ART pregnancies may lead to unnecessary amniocentesis.
AIM: Quadruple test is used for Down's syndrome screening in the second trimester of pregnancy. The aim of this study was to investigate differences in quadruple test parameters between pregnancies achieved by assisted reproductive treatments (ART) and spontaneous conception. MATERIALS AND METHODS: We retrospectively compared levels of alfa-fetoprotein (AFP), unconjugated Estriol (uE3), inhibin-A and hCG and also screen positive test results. RESULTS: Levels of all quadruple test parameters were statistically significantly increased in ART pregnancies when compared to spontaneous pregnancies, AFP was 1.4±0.74 and 1.16±0.53, (p=0.001), uE3 was 1.10±0.37 and 1.00±0.28, (p=0.004), hCG was 1.56±1.04 and 1.26±0.76, (p=0.001), inhibin A was 1.38±0.76 and 1.08±0.57, (p=0.001), screen positive tests were nearly doubled (4.8% and 8.4%). CONCLUSIONS: Increased screen positive test results and quadruple test parameters in ART pregnancies may lead to unnecessary amniocentesis.
Entities:
Keywords:
AFP; ART; estriol; hCG; inhibin-A; quadruple test
Authors: R Räty; A Virtanen; P Koskinen; L Anttila; J Forsström; P Laitinen; P Mörsky; A Tiitinen; U Ekblad Journal: Hum Reprod Date: 2002-02 Impact factor: 6.918