Evaluation and refinement of a field-portable drinking water toxicity sensor utilizing electric cell-substrate impedance sensing and a fluidic biochip.

Mark W Widder1, Linda M Brennan1, Elizabeth A Hanft2, Mary E Schrock2, Ryan R James2, William H van der Schalie1.   

Abstract

The US Army's need for a reliable and field-portable drinking water toxicity sensor was the catalyst for the development and evaluation of an electric cell-substrate impedance sensing (ECIS) device. Water testing technologies currently available to soldiers in the field are analyte-specific and have limited capabilities to detect broad-based water toxicity. The ECIS sensor described here uses rainbow trout gill epithelial cells seeded on fluidic biochips to measure changes in impedance for the detection of possible chemical contamination of drinking water supplies. Chemicals selected for testing were chosen as representatives of a broad spectrum of toxic industrial compounds. Results of a US Environmental Protection Agency (USEPA)-sponsored evaluation of the field portable device were similar to previously published US Army testing results of a laboratory-based version of the same technology. Twelve of the 18 chemicals tested following USEPA Technology Testing and Evaluation Program procedures were detected by the ECIS sensor within 1 h at USEPA-derived human lethal concentrations. To simplify field-testing methods further, elimination of a procedural step that acclimated cells to serum-free media streamlined the test process with only a slight loss of chemical sensitivity. For field use, the ECIS sensor will be used in conjunction with an enzyme-based sensor that is responsive to carbamate and organophosphorus pesticides.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  ECIS; RTgill-W1; fluidic biochip; impedance; in vitro toxicology; rainbow trout gill epithelial cells; toxicity sensor; water toxicity

Mesh:

Substances:

Year:  2014        PMID: 25231170     DOI: 10.1002/jat.3017

Source DB:  PubMed          Journal:  J Appl Toxicol        ISSN: 0260-437X            Impact factor:   3.446


  2 in total

1.  Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.

Authors:  Linda M Brennan; Mark W Widder; Michael K McAleer; Michael W Mayo; Alex P Greis; William H van der Schalie
Journal:  J Vis Exp       Date:  2016-03-07       Impact factor: 1.355

Review 2.  Towards improved biomonitoring tools for an intensified sustainable multi-use environment.

Authors:  Jan Roelof van der Meer
Journal:  Microb Biotechnol       Date:  2016-07-29       Impact factor: 5.813

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.