Literature DB >> 25226973

An efficient and accurate approach for fabricating dental implant surgical guides.

Wei-chen Lee1, Ching-Hang Huang1, Shan-Chen Chung1, Ching-chih Wei1.   

Abstract

The aim of this research was to develop an efficient and accurate method to fabricate a dental implant surgical guide. The surgical guide is adapted from the patient's vacuum-formed clear template with the use of a plate with three ceramic balls, a six-axis drilling machine and its fixture. The plate, with the ceramic balls used as radiographic markers, is glued to the template, and the patient bites this template during a CT scan. Then, the surgeon can plan the locations and orientations of the implants on the CT-based model in the dental planning software. The drilling information is exported directly to the computer-controlled drilling machine for subsequent drilling on the template to complete the surgical guide. This method allows the surgical guide to be made without any measurements, which reduces the fabrication time, but increases the drilling accuracy. The preliminary results show that the average location error was 0.31 ± 0.17 mm and the average orientation error was 0.53 ± 0.24°, which can be considered accurate in comparison with the results reported in the literature.

Entities:  

Keywords:  Dental implant surgical guide; drilling machine; fixture; radiographic marker; vacuum-formed template

Mesh:

Substances:

Year:  2014        PMID: 25226973     DOI: 10.3233/BME-141086

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  3 in total

1.  Biopsies of osseous jaw lesions using 3D-printed surgical guides: a clinical study.

Authors:  Lukas Postl; Thomas Mücke; Stefan Hunger; Sabina Noreen Wuersching; Svenia Holberg; Oliver Bissinger; Rainer Burgkart; Michael Malek; Stefan Krennmair
Journal:  Eur J Med Res       Date:  2022-07-02       Impact factor: 4.981

2.  In-house 3D-printed surgical guides for osseous lesions of the lower jaw: an experimental study.

Authors:  Lukas Postl; Thomas Mücke; Stefan Hunger; Oliver Bissinger; Michael Malek; Svenia Holberg; Rainer Burgkart; Stefan Krennmair
Journal:  Eur J Med Res       Date:  2021-03-15       Impact factor: 2.175

3.  Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial.

Authors:  Jinyou Chai; Xiaoqian Liu; Ramona Schweyen; Jürgen Setz; Shaoxia Pan; Jianzhang Liu; Yongsheng Zhou
Journal:  BMC Oral Health       Date:  2020-10-21       Impact factor: 2.757

  3 in total